Closing the gap in plan quality: Leveraging deep‐learning dose prediction for adaptive radiotherapy

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Balancing quality and efficiency has been a challenge for online adaptive therapy. Most systems start the online re‐optimization with the original planning goals. While some systems allow planners to modify the planning goals, achieving a high‐quality plan within time constraints remains a common barrier.
Sean J. Domal   +9 more
wiley   +1 more source

Stereotactic radiotherapy for metastatic brain tumors: A comparative analysis of dose distributions among VMAT, Helical TomoTherapy, CyberKnife, Gamma Knife, and ZAP‐X

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract This study evaluates various radiotherapy techniques for treating metastatic brain tumor (BT), focusing on non‐coplanar volumetric modulated arc radiotherapy (NC‐VMAT), coplanar VMAT (C‐VMAT), Helical TomoTherapy (HT), CyberKnife (CK), Gamma Knife (GK), and ZAP‐X.
Toshihiro Suzuki   +9 more
wiley   +1 more source

The design and fabrication of 81.25 MHz RFQ for Low Energy Accelerator Facility

open access: yesNuclear Engineering and Technology, 2019
To provide high shunt impendence with low power losses, an 81.25 MHz continuous wave (CW) radio frequency quadrupole (RFQ) accelerator has been designed and machined as parts of the Low Energy Accelerator Facility (LEAF).
Bo Zhao   +7 more
doaj  

Impact of acceleration treatment on treatment plan and delivery qualities in tomotherapy for lung cancer

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background Acceleration treatment (AT) is a novel treatment planning parameter introduced in the tomotherapy‐dedicated treatment planning system, Precision. This study explores the effects of AT on tomotherapy plans using helical (TomoHelical) and direct (TomoDirect) irradiation techniques.
Ryosuke Shirata   +9 more
wiley   +1 more source

Dose rate correction of a diode array for universal wedge field dosimetric verification

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose To study the performance of MapCHECK 3 (MC3) in measuring universal wedge fields and propose a dose rate correction strategy to improve MC3 measurement accuracy. Materials and methods Universal wedge fields with different wedge angles and field sizes were measured at different depths using MC3.
Linyi Shen   +6 more
wiley   +1 more source

Bone‐wise rigid registration of femur, tibia, and fibula for the tracking of temporal changes

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background Multiple myeloma (MM) induces temporal alterations in bone structure, such as osteolytic bone lesions, which are challenging to identify through manual image interpretation. The large variation in radiologists' assessments, even at expert centers, further complicates diagnosis.
Arttu Ruohola   +5 more
wiley   +1 more source

Exploring surface‐guided systems for intelligent breathing‐adapted four‐dimensional computed tomography: A comparison to infrared‐based reflective marker systems

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study evaluates the technical feasibility of adapting a surface monitoring system, designed for conventional four‐dimensional computed tomography (4DCT), to an intelligent, breathing‐adapted 4DCT and examines its potential to expand the currently limited range of supported surrogate systems.
Niklas Lackner   +4 more
wiley   +1 more source