Results 21 to 30 of about 1,029,186 (289)
A small footprint couch‐top support device for image‐guided radiotherapy of heavy patients
Abstract Purpose Patients with body weights close to or above 400 lbs present unique challenges in radiation therapy since the weight limit of most treatment couches decreases as the couch‐top extends toward the treatment gantry. The purpose of this work was to develop a small footprint couch‐top support platform to safely perform image‐guided ...
Huixiao Chen+5 more
wiley +1 more source
Abstract Background and purpose For postoperative breast cancer patients, deformable image registration (DIR) is challenged due to the large deformations and non‐correspondence caused by tumor resection and clip insertion. To deal with it, three metrics (fiducial‐, region‐, and intensity‐based) were jointly used in DIR algorithm for improved accuracy ...
Xin Xie+6 more
wiley +1 more source
Reassigning the shapes of the 0+ states in the 186Pb nucleus
The authors study an interesting phenomena of shape coexistence in 186Pb. In an elegant and well-documented experiment, they confirm the coexistence of the three 0+ states in the 186Pb nucleus and reassign the shapes associated with the excited 0+ states.
Joonas Ojala+39 more
doaj +1 more source
Abstract Purpose MRI is increasingly used for brain and head and neck radiotherapy treatment planning due to its superior soft tissue contrast. Flexible array coils can be arranged to encompass treatment immobilization devices, which do not fit in diagnostic head/neck coils. Selecting a flexible coil arrangement to replace a diagnostic coil should rely
Evangelia Kaza+6 more
wiley +1 more source
Clinical commissioning of an adaptive radiotherapy platform: Results and recommendations
Abstract Online adaptive radiotherapy platforms present a unique challenge for commissioning as guidance is lacking and specialized adaptive equipment, such as deformable phantoms, are rare. We designed a novel adaptive commissioning process consisting of end‐to‐end tests using standard clinical resources.
Kelly Kisling+5 more
wiley +1 more source
Statistical process control to monitor use of a web‐based autoplanning tool
Abstract Purpose To investigate the use of statistical process control (SPC) for quality assurance of an integrated web‐based autoplanning tool, Radiation Planning Assistant (RPA). Methods Automatically generated plans were downloaded and imported into two treatment planning systems (TPSs), RayStation and Eclipse, in which they were recalculated using ...
Hunter Mehrens+5 more
wiley +1 more source
Treatment planning with a 2.5 MV photon beam for radiation therapy
Abstract Purpose The shallow depth of maximum dose and higher dose fall‐off gradient of a 2.5 MV beam along the central axis that is available for imaging on linear accelerators is investigated for treatment of shallow tumors and sparing the organs at risk (OARs) beyond it.
Navid Khaledi+5 more
wiley +1 more source
CLICdp Overview. Overview of physics potential at CLIC
CLICdp, the CLIC detector and physics study, is an international collaboration presently composed of 23 institutions. The collaboration is addressing detector and physics issues for the future Compact Linear Collider (CLIC), a high-energy electron ...
Levy Aharon
doaj +2 more sources
Volume staging for arteriovenous malformation SRS treatment using VMAT
Abstract Volume staging involves dividing the target volume into smaller parts and treating each part separately. In this study, the feasibility of volume‐staged stereotactic radiosurgery (VS‐SRS) on a linear accelerator using volumetric modulated arc therapy (VMAT) and a frameless patient positioning system is investigated.
Claudia Mendez, Ermias Gete
wiley +1 more source
Abstract This study aimed to evaluate the clinical beam commissioning results and lateral penumbra characteristics of our new pencil beam scanning (PBS) proton therapy using a multi‐leaf collimator (MLC) calculated by use of a commercial Monte Carlo dose engine.
Yuki Tominaga+5 more
wiley +1 more source