Results 61 to 70 of about 23,022 (216)

Effect of osteoporosis-related reduction in the mechanical properties of bone on the acetabular fracture during a sideways fall: A parametric finite element approach.

open access: yesPLoS ONE, 2022
PurposeThe incidence of acetabular fractures due to low-energy falls is increasing among the geriatric population. Studies have shown that several biomechanical factors such as body configuration, impact velocity, and trochanteric soft-tissue thickness ...
Shahab Khakpour   +5 more
doaj   +1 more source

Hip-joint simulator accurately duplicates human walking pattern [PDF]

open access: yes, 1975
Device simulates all three motions of walking and provides realistic variable loading during each step.
Johnson, B. L., Swikert, M. A.
core   +1 more source

How Can Technology Improve Acetabular and Pelvic Fractures Management in the Operating Room? A Systematic Review

open access: yesOrthopaedic Surgery, EarlyView.
New technologies are very attractive and are a promising help in pelvic and acetabular fractures surgery. Their results demonstrated greater surgical accuracy without increasing complications and need to be improved before being included in routine care.
Marie Le Baron   +3 more
wiley   +1 more source

Quadrilateral plate classification program of acetabular fractures based on three-column classification: a three-dimensional fracture mapping study

open access: yesJournal of Orthopaedic Surgery and Research
Background A new classification system for acetabular fractures has been proposed in recent years, which is called the 3-column classification. However, this system does not provide information regarding quadrilateral plate fractures.
Ruihan Wang   +5 more
doaj   +1 more source

Expert Consensus on Trendelenburg Position Postless Hip Distraction Technique in Hip Arthroscopy

open access: yesOrthopaedic Surgery, EarlyView.
This work evaluates the Trendelenburg position postless hip distraction technique for hip arthroscopy, highlighting its safety, efficacy, cost‐effectiveness, and key clinical application points. ABSTRACT Postless hip distraction technique is a novel traction method for hip arthroscopy developed in recent years.
Yaoting Wang   +11 more
wiley   +1 more source

Efficacy Comparison of Open Reduction and Robot‐Aided Infra‐Acetabular and Posterior Column Screws Fixation in Complex Acetabular Fractures Surgery: Union Plate Versus Reconstruction Plate

open access: yesOrthopaedic Surgery, EarlyView.
Robot‐aided technology allowed for precise and minimally invasive placement of periarticular long screws in open surgery for complex acetabular fractures, while using the Union Plate could decrease operation difficulty (fewer channel adjustments, less time for robotic manipulation and intraoperative plate contouring), operation time, and bleeding.
Jianan Chen   +8 more
wiley   +1 more source

Literature Review and Clinical Presentation of Bilateral Acetabular Fractures Secondary to Seizure Attacks

open access: yesCase Reports in Orthopedics, 2012
Central acetabular fracture dislocation is usually caused by high-energy external trauma. However, 26 cases that occurred as a result of a seizure attack appeared in the literature from 1970 to 2007, with the seizure attacks themselves caused by many ...
Alexandre H. Nehme   +5 more
doaj   +1 more source

Articular impaction injuries in the lower limb [PDF]

open access: yes, 2017
The effective management of articular impacted fractures requires the successful elevation of the osteochondral fragment to eliminate joint incongruency and the stable fixation of the fragments providing structural support to the articular surface.The ...
Giannoudis, PV, Pountos, I
core   +1 more source

Timing of intrapartum transfusion among obstetric patients, stratified by admission and discharge haemoglobin, relative to anaesthesia care: A retrospective cohort study

open access: yesTransfusion Medicine, EarlyView.
Abstract Background We previously validated and implemented criteria for auditing anaesthesiologists with intraoperative transfusion based on low median blood loss of the surgical procedure or absence of anaemia before transfusion. However, obstetrical cases were excluded during implementation, as the peripartum blood management protocol does not ...
Franklin Dexter   +2 more
wiley   +1 more source

Subsidence of the BFX standard stem after canine total hip replacement: A case series of 177 consecutive procedures

open access: yesVeterinary Surgery, EarlyView.
Abstract Objective To describe postoperative subsidence observed after total hip replacement (THR) with the BFX standard stem. Study design Retrospective case series. Sample population A total of 177 THR procedures in 145 dogs. Methods Clinical and radiographic follow‐up data were collected between 12 weeks and six months postoperatively.
Daniel Low   +2 more
wiley   +1 more source

Home - About - Disclaimer - Privacy