Results 21 to 30 of about 12,242,418 (262)

Universal Current-Conveyor-Based Current-Mode Filters with Single Input and Three Outputs

open access: yesActive and Passive Electronic Components, 1998
Universal active current-mode filters with single input and three outputs are presented. The proposed filters avoid the use of external feedback in any part of the circuit and use grounded resistors and grounded capacitors.
Muhammad Taher Abuelma'atti   +1 more
doaj   +1 more source

Novel Current-Conveyor-Based Universal Current-Mode Biquad Filter with Three Inputs and One Output

open access: yesActive and Passive Electronic Components, 1998
A novel universal current-mode filter with three inputs and one high imedance output is presented. The proposed circuit uses four plus-type second-generation current-conveyors, grounded resistors and grounded capacitors.
Muhammad Taher Abuelma'atti   +1 more
doaj   +1 more source

Precision Full-Wave Rectifiers with Current Active Elements and Current Biasing

open access: yesInternational Journal of Advances in Telecommunications, Electrotechnics, Signals and Systems, 2013
This article discusses universal precision rectifiers using current active elements and current sources for the diode excitation. The paper introduces circuit solution of the universal precision full-wave rectifier with intention to reduce negative ...
Lukas Langhammer, Jan Jerabek
doaj   +1 more source

Improved Weighted Average Current Control Strategy For LCL Grid-Connected Inverters

open access: yesJournal of Applied Science and Engineering, 2023
The weighted average current control strategy has attracted much attention because of its lower-order effect on grid-connected inverters. However, the system reverse resonant peak caused by digital control delay causes the traditional WAC control to fail,
Jie Yang, Wentao Han, Ming Yang
doaj   +1 more source

Current status of active surveillance in prostate cancer [PDF]

open access: yesInvestigative and Clinical Urology, 2016
Active surveillance (AS) is a management strategy involving close monitoring the course of disease with the expectation to intervene if the cancer progress, in a super-selected group of low-risk prostate cancer (PCa) patients.
Mun Su Chung, Seung Hwan Lee
doaj   +1 more source

Electrode Kinetic Data: Geometric vs. Real Surface Area

open access: yesBatteries, 2022
Kinetic data reporting the rate of electron transfer across an electrified interface are of fundamental as well as practical importance. They report the electric current caused by coupling the flow of electrons inside the electronically conducting ...
Xuan Xie, Rudolf Holze
doaj   +1 more source

Research of robust repetitive current control strategy of active power filter

open access: yesGong-kuang zidonghua, 2014
In view of problems of steady-state error and phase offset of traditional current loop PI control of active power filter, a robust repetitive current control strategy of active power filter was proposed, and concrete implementation method of robust ...
RONG Xiang
doaj   +1 more source

An Active Resistor With a Lower Sensitivity to Process Variations, and its Application in Current Reference

open access: yesIEEE Access, 2020
A novel active resistor circuit offering less sensitivity to process and temperature variations without any extra trimming is proposed. The circuit consists of two accurately matched, high resistance polysilicon (hripoly) resistors and a voltage ...
Vilem Kledrowetz   +3 more
doaj   +1 more source

Current Therapeutic Options in Active Moderate-to-Severe Thyroid-Associated Ophthalmopathy

open access: yesActa Medica Bulgarica, 2023
Active moderate-to-severe TAO is a disease, the treatment of which requires a multidisciplinary team, an individualized approach and strict follow-up, yet it is often suboptimal.
Stoynova M., Shinkov A., Kovatcheva R.
doaj   +1 more source

Cascaded Voltage and Current Control for a Dual Active Bridge Converter with Current Filters

open access: yesEnergies, 2021
The paper describes the cascaded voltage and current control for a bidirectional DC/DC converter in Dual Active Bridge (DAB) topology. The typical DAB converter circuit was extended by additional current filters, which allow it to operate in application ...
Michal Gierczynski   +2 more
doaj   +1 more source

Home - About - Disclaimer - Privacy