Results 11 to 20 of about 1,635,837 (95)
Adaptive single-phase auto-reclosing method using power line carrier signals
Abstract This paper proposes a new method for adaptive single-phase auto-reclosing (ASPAR) that improves the rate of successful reclosing actions after the occurrence of a transient single-phase fault and prevents unsuccessful reclosing. After the occurrence of a fault, the only faulty phase is disconnected by the protection system (e.g., distance ...
Reza Jalilzadeh Hamidi, Hanif Livani
openaire +2 more sources
This study presents the results of single‐phase auto reclosing technique tests, comparing the performance of traditional procedure and fast adaptive procedure. The last is based on the measurement of voltage harmonic content on the transmission line faulty phase terminals.
Ozenir Dias, Maria Cristina Tavares
openaire +2 more sources
An efficient deep learning based scheme for adaptive auto-reclosing in power transmission lines
As a large percentage of faults in transmission lines are single-line-to-ground (SLG) and transient in nature, the use of adaptive single-phase auto-reclosing (ASPAR) schemes is essential. In this paper, a new scheme for ASPAR is proposed to improve the stability and reliability of power transmission lines.
Farhad Hatami Aloghareh +2 more
openaire +3 more sources
This paper presents an algorithm for adaptive determination of the dead timeduring transient arcing faults and blocking automatic reclosing during permanent faults onoverhead transmission lines. The discrimination between transient and permanent faults ismade by the zero sequence voltage measured at the relay point.
S. Jamali, A. Parham
openaire +2 more sources
An adaptive reclosing scheme based on phase characteristics for MMC-HVDC systems [PDF]
To improve the reliability of power supply, reclosing schemes are required after transient faults, which commonly occur in overhead line based high voltage DC (HVDC) systems.
Li, Rui, Lv, Wenxuan, Zheng, Tao
core +3 more sources
A Current-Commutation DC Circuit Breaker with Adaptive Reclosing Capability [PDF]
DC faults are critical events in a flexible high-voltage dc (HVDC) grid. Thus, ensuring that the power system returns to normal operation rapidly and reliably after fault isolation is very important. This requires a HVDC breaker. In overhead line systems
Chengyong Zhao +3 more
core +1 more source
Guidelines for the use of flow cytometry and cell sorting in immunological studies (third edition)
Abstract The third edition of Flow Cytometry Guidelines provides the key aspects to consider when performing flow cytometry experiments and includes comprehensive sections describing phenotypes and functional assays of all major human and murine immune cell subsets.
Andrea Cossarizza +192 more
wiley +1 more source
Adaptive Self‐Sealing Suction‐Based Soft Robotic Gripper
A minimalistic suction cup design that can be used as a universal soft robotic gripper is proposed. The gripper has a thin and flat elastic membrane, which does not only create an adaptive self‐sealing with parts smaller than the gripper diameter, but can also show enhanced suction on various textured surfaces and grasping various real‐world 3D objects
Sukho Song +4 more
wiley +1 more source
Abstract Reliable and dedicated protection of the transformer is the main requirement in the power system due to the supervision of a highly expensive equipment transformer. Non‐linear characteristics of the transformer give mysterious behaviour for the period of inrush and Current transformer saturation conditions.
Maulik Raichura +2 more
wiley +1 more source
An adaptive reclosing strategy for MMC-HVDC systems with hybrid DC circuit breakers [PDF]
Modular multilevel converter (MMC) based high voltage direct current transmission (HVDC) is an effective solution for large-scale renewable power integration over long-distance. In the overhead MMC-HVDC systems, the high voltage DC circuit breakers (DCCB)
Yang, Saizhao +4 more
core +2 more sources

