Results 41 to 50 of about 5,625 (121)
Permanent Fault Identification Scheme for Distribution Feeders Using Detection‐Based Reclosing
This paper proposes a novel permanent fault identification scheme based on detection‐based reclosing to mitigate the risks of blind three‐phase reclosing and overcome the sensitivity limitations of existing methods. ABSTRACT To mitigate secondary damage caused by reclosing a distribution line with a permanent fault, a highly sensitive fault property ...
Zhongxue Chang +3 more
wiley +1 more source
Blood‐ and red blood cell (RBC)‐derived colloids are promising biomedical materials but are structurally complex. This work demonstrates how small‐ and ultra‐small‐angle neutron scattering (SANS and USANS) with contrast variation reveal the micro/nanoarchitectures of RBC ghosts, extracellular vesicles (EVs), and plasma proteins.
Cuong Viet Pham +10 more
wiley +1 more source
The scheme of single-phase adaptive reclosing on EHV/UHV transmission lines [PDF]
Automatic reclosure (AR) is extremely effective in improving the reliability, stability and security of the overall power system. However, the present autoreclosure operates blindly and practices employing a fixed time.
Bin, Li +3 more
core +1 more source
Field analysis of directionality measurement with inverter based resources in India
The detection of directionality in distance relay and response for various type of system faults is a key area to be considered. The objective of this paper is to analyse the performance of directional elements in a distance protection for a distributed energy resource connected system in India.
Ashoka Shyamaprasad +3 more
wiley +1 more source
Gating residues govern ligand unbinding kinetics from the buried cavity in HIF‐2α PAS‐B
Abstract While transcription factors have been generally perceived as “undruggable,” an exception is the HIF‐2 hypoxia‐inducible transcription factor, which contains an internal cavity that is sufficiently large to accommodate a range of small‐molecules, including the therapeutically used inhibitor belzutifan. Given the relatively long ligand residence
Marion L. Silvestrini +7 more
wiley +1 more source
An adaptive reclosing strategy for MMC-HVDC systems with hybrid DC circuit breakers [PDF]
Modular multilevel converter (MMC) based high voltage direct current transmission (HVDC) is an effective solution for large-scale renewable power integration over long-distance. In the overhead MMC-HVDC systems, the high voltage DC circuit breakers (DCCB)
Yang, Saizhao +4 more
core
In order to address the problem of CT saturation, a novel measurement‐protection‐integrated current transformer (MPICT) is proposed. To verify the feasibility and effectiveness of the MPICT, a series of theoretical analyses, 3D FEM simulations and laboratory tests are conducted.
Zhexuan Zhang +4 more
wiley +1 more source
Authoring courses with rich adaptive sequencing for IMS learning design [PDF]
This paper describes the process of translating an adaptive sequencing strategy designed using Sequencing Graphs to the semantics of IMS Learning Design. The relevance of this contribution is twofold.
Delgado-Kloos, Carlos +7 more
core +1 more source
A capacitor-based DC circuit breaker for HVDC power grid [PDF]
DC circuit breakers (DCCBs) are the critical equipment to isolate faults in high-voltage DC grids. The improvement of interruption performances of capacitor-based DCCBs (C-DCCBs) has been widely researched.
Xu, Zhuang +3 more
core +1 more source
A feasibility study of an adaptive reclosing relay [PDF]
Logic for an adaptive reclosing relay has been developed. The relay works correctly in a wide number of fault cases. The relay has the following distinguishing characteristics : (a) Reclosing into a three phase fault is avoided under all circumstances.
Vaidyanathan, Sundararaman
core

