Results 11 to 20 of about 6,023,413 (342)
Generally, the fault current supplied by inverter-based renewable energy sources (IBRES) and electrical storage systems (ESS) is about 1.2 to 2 times their rated current and much lower than synchronous generators because the former acts as a current ...
Wookyu Chae +5 more
doaj +2 more sources
The IEC 61850 communication standard is getting popular for application in electric power substation automation. This paper focuses on the potential application of the IEC 61850 generic object-oriented substation event (GOOSE) protocol in the AC ...
Aushiq Ali Memon, Kimmo Kauhaniemi
doaj +2 more sources
Additively Manufactured Dual-Faced Structured Fabric for Shape-Adaptive Protection. [PDF]
Fabric‐based materials have demonstrated promise for high‐performance wearable applications but are currently restricted by their deficient mechanical properties.
Tian Y +15 more
europepmc +2 more sources
µPMU-based smart adaptive protection scheme for microgrids
The concepts of microgrids (MGs) and smart grid represent the recent targeted revolution towards fully smart electrical network integrated with high penetration of renewable energy sources (RESs).
Mohamed Salah Elbana +3 more
doaj +2 more sources
Hepatic Autophagy Deficiency Remodels Gut Microbiota for Adaptive Protection via FGF15-FGFR4 Signaling. [PDF]
Background & Aims The functions of the liver and the intestine are closely tied in both physiological and pathologic conditions. The gut microbiota (GM) often cause deleterious effects during hepatic pathogenesis.
Yan S +5 more
europepmc +2 more sources
Protection schemes are essential in active distribution networks and microgrids’ reliable, efficient, and flexible operation. However, the protection of these networks presents significant challenges due to operational changes, such as variations in ...
A. Barranco-Carlos +4 more
semanticscholar +1 more source
Microgrids (MGs) suffer from unpredictable faults on the feeders for various random reasons. These faults could obstruct the stability of the MG operation and damage the components. Moreover, many uncertainties elements affect the MG’s response to faults,
A. Hatata, M. Abd-Elnaby, B. E. Sedhom
semanticscholar +1 more source
Coordination of Directional Over Current Relays (DOCR) is an important issue in the protection of power systems. In this paper, the object function of DOCR has been modified for better coordination.
Ozan Akdağ, C. Yeroğlu
semanticscholar +1 more source
Recently, numerical relays with communication capabilities have been employed to provide adaptive solutions for Distributed Generations (DGs) protection issues.
A. H. El-Hamrawy +2 more
semanticscholar +1 more source
This paper proposes an adaptive protection scheme (APS) based on the original heap-based optimization (HBO) and a modified HBO (MHBO). APS is used to solve protection relays coordination problems that include directional overcurrent relays (DOCRs) as ...
M. Abdelhamid +3 more
semanticscholar +1 more source