Results 101 to 110 of about 951,780 (206)

Hypertensive phase and early complications after Ahmed glaucoma valve implantation with intraoperative subtenon triamcinolone acetonide

open access: yes, 2014
Angela V Turalba,1,2 Louis R Pasquale1,2 1Department of Ophthalmology, Massachusetts Eye and Ear Infirmary, Boston, MA, USA; 2Department of Ophthalmology, Harvard Medical School, Boston, MA, USA Objective: To evaluate intraoperative subtenon ...
Turalba AV, Pasquale LR
core  

Level of vascular endothelial growth factor in aqueous humor and surgical results of ahmed glaucoma valve implantation in patients with neovascular glaucoma.

open access: yes, 2009
PURPOSE: To determine the associations between the levels of growth factors in aqueous humor and the surgical outcomes of Ahmed glaucoma valve implantation in patients with neovascular glaucoma (NVG).
홍사민   +13 more
core   +1 more source

Vitreous Prolapse Following Choroidal Effusion after Ahmed Glaucoma Valve Surgery: A Case Report [PDF]

open access: yes, 2022
Vitreous prolapse is a condition in which the vitreous gel is displaced into the anterior chamber, typically caused by a ruptured posterior lens capsule or a zonular defect.
Yadgari, Maryam, Yazdani, Ehsan
core  

Management of refractive neovascular glaucoma using the Ahmed valve. Short-term clinical experience in a reference center [Manejo del glaucoma neovascular refractario empleando la válvula de Ahmed. Experiencia clínica de corto plazo en un centro de referencia]

open access: yes, 2004
Purpose: To assess the short-term efficacy and safety of Ahmed valve to control intraocular pressure (IOP) in eyes affected by neovascular glaucoma. Methods: A retrospective review of 521 consecutive cases of Mexican patients who underwent Ahmed valve ...
Gil-Carrasco, F.   +4 more
core   +1 more source

Is Ahmed Glaucoma Valve Consistent in Performance?

open access: yesTranslational Vision Science & Technology, 2018
To investigate the mechanism of action and consistency in flow characteristics of the Ahmed glaucoma valve (AGV) under simulated physiological conditions in-vitro and to evaluate whether resistance during priming has any effect on performance of the device.Each newly opened AGV device was connected to a digital manometer and was primed with normal ...
Choudhari, Nikhil S.   +5 more
openaire   +2 more sources

Publication Only

open access: yes
HemaSphere, Volume 10, Issue S1, June 2026.
wiley   +1 more source

Recurrent encapsulation after Ahmed glaucoma valve implantation in a patient with Schwartz–Matsuo syndrome

open access: yesThe Pan-American Journal of Ophthalmology
Glaucoma drainage devices (GDDs) are an important tool for the treatment of complicated/refractory glaucoma cases. Excessive capsular fibrosis is a frequent cause of long-term failure of Ahmed® glaucoma valve (AGV) that is difficult to manage and often ...
Ana Rita Viana   +3 more
doaj   +1 more source

ePoster

open access: yes
European Journal of Neurology, Volume 33, Issue S1, June 2026.
wiley   +1 more source

Comparison of Silicone- and Porous-Plate Ahmed Glaucoma Valves

open access: yesMedical Devices: Evidence and Research, 2020
Tina M Roa,1 Peter A Netland,1 Vital P Costa,2 Steven R Sarkisian Jr,3 Lama A Al-Aswad,4 Marlene R Moster,5 Iqbal IK Ahmed6 1Department of Ophthalmology, University of Virginia School of Medicine, Charlottesville, VA 22908, USA; 2Department of ...
Roa TM   +6 more
doaj  

Glaucoma valve implants in Nigerians a report of early experience with the Ahmed glaucoma valve

open access: yes, 2006
Objective: To show the value of glaucoma valve implant surgery in the management of glaucoma in Nigerians. Design: A prospective study of two glaucoma patients who had an Ahmed glaucoma valve implant at the University of Benin Teaching Hospital and DDS ...
IO Chukwuka   +5 more
core   +1 more source

Home - About - Disclaimer - Privacy