Results 111 to 120 of about 2,911 (207)

Management of implant plate exposure of silicone Ahmed glaucoma valve: a review of six cases

open access: yes, 2016
Objective: To describe the management options for exposed silicone Ahmed glaucoma valve (AGV) implant.Methods: This was carried out as a retrospective chart review at a tertiary care eye hospital in Southern India. Medical records of six subjects managed
Roy, Avik Kumar   +3 more
core   +1 more source

Surgical outcomes of glaucoma drainage device surgery in an African context

open access: yesAfrican Vision and Eye Health
Background: The use of glaucoma drainage devices (GDDs) in the management of glaucoma is increasing; however, there is a paucity of data comparing the surgical outcomes of different devices in an African context.
Tshilidzi van der Lecq   +3 more
doaj   +1 more source

Tackling the tubes of refractory Sturge–Weber syndrome with secondary glaucoma: A surgeon’s nightmare!

open access: yesIndian Journal of Ophthalmology. Case Reports
Hypotony with shallow anterior chamber (AC) post glaucoma surgery in Sturge–Weber syndrome (SWS) patients is commonly due to choroidal effusions.
Dewang Angmo   +3 more
doaj   +1 more source

Outcome of Ahmed Valve Implantation in Refractory Glaucoma

open access: yes, 2007
Purpose: To evaluate the outcome of Ahmed valve implantation as a primary or secondary glaucoma surgery to treat refractory glaucoma patients. Methods: A total of 101 eyes of 101 patients with refractory glaucoma, who received Ahmed valve implantation ...
마경탁
core  

ePosters

open access: yes
European Journal of Neurology, Volume 31, Issue S1, June 2024.
wiley   +1 more source

Management of refractive neovascular glaucoma using the Ahmed valve. Short-term clinical experience in a reference center [Manejo del glaucoma neovascular refractario empleando la válvula de Ahmed. Experiencia clínica de corto plazo en un centro de referencia]

open access: yes, 2004
Purpose: To assess the short-term efficacy and safety of Ahmed valve to control intraocular pressure (IOP) in eyes affected by neovascular glaucoma. Methods: A retrospective review of 521 consecutive cases of Mexican patients who underwent Ahmed valve ...
Gil-Carrasco, F.   +4 more
core   +1 more source

Post-operative results of AHMED valve implantation in glaucoma patients in a center in northeastern Colombia [PDF]

open access: yes, 2019
El glaucoma es una causa importante de ceguera irreversible alrededor del mundo. En el 2010, se reportó 6.5% de ceguera debido al glaucoma. Sin embargo, la ceguera puede ser prevenible realizando un diagnóstico temprano y estableciendo un tratamiento ...
Castellanos Castellanos, Yuly Andrea
core  

Surgical outcomes associated with a sutureless drainage valve implantation procedure in patients with refractory glaucoma

open access: yesClinical Ophthalmology, 2018
Caroline N Pham,1 Nathan M Radcliffe,1–3 Daniel M Vu2 1New York University, New York, NY, USA; 2Weill Cornell Medical College, New York, NY, USA; 3New York Eye Surgery Center, New York, NY, USA Purpose: To evaluate the safety and efficacy profile
Pham CN, Radcliffe NM, Vu DM
doaj  

Ahmed glaucoma valve with adjunctive amniotic membrane for refractory glaucoma.

open access: yesJournal of ophthalmic & vision research, 2010
To evaluate the efficacy and safety of Ahmed Glaucoma Valve (AGV) implantation with adjunctive use of preserved amniotic membrane for surgical management of refractory glaucoma.Seven patients (5 female subjects) with refractory glaucoma were included in the study.
Heydar Amini   +4 more
openaire   +2 more sources

Comparison Between the eyeWatch Device and the Ahmed Valve in Refractory Glaucoma

open access: yes
Purpose: To assess the efficacy and safety of a glaucoma procedure to control intraocular pressure (IOP) using the adjustable eyeWatch glaucoma drainage device compared with Ahmed glaucoma valve (AGV) in refractory glaucoma.
Mermoud, Andre   +7 more
core   +1 more source

Home - About - Disclaimer - Privacy