Background Late subluxation of an intraocular lens (IOL) within the capsular bag is a rare complication of cataract surgery, primarily associated with progressive zonular weakening in conditions such as pseudoexfoliation syndrome, high myopia, prior ...
Ahnul Ha +4 more
doaj +1 more source
Fuchs heterochromic iridocyclitis-associated glaucoma: a retrospective comparison of primary Ahmed glaucoma valve implantation and trabeculectomy with mitomycin C [PDF]
Hamed Esfandiari +7 more
openalex +1 more source
Long-term success of ahmed glaucoma valve in refractory glaucoma.
To evaluate the long-term results and complications of ahmed glaucoma valve (AGV) implantation in refractory glaucoma.A retrospective review of 13 patients (13 eyes) with refractory glaucoma who underwent AGV implantation and had a minimum follow-up of 18 months was performed. All patients underwent a complete ophthalmologic examination and intraocular
ÖZBEK, ZEYNEP +3 more
openaire +2 more sources
Needle revision with 5-fluorouracil for the treatment of ahmed glaucoma valve filtering blebs 5-fluoruracil needling revision can be a useful and safe tool in the management of failing ahmed glaucoma valve filtering blebs [PDF]
Floriani, Irene +5 more
core +1 more source
Ahmed Glaucoma Valves versus EX-PRESS Devices in Glaucoma Secondary to Silicone Oil Emulsification [PDF]
Zhuyun Qian +3 more
openalex +1 more source
Ahmed glaucoma valve with adjunctive amniotic membrane for refractory glaucoma.
To evaluate the efficacy and safety of Ahmed Glaucoma Valve (AGV) implantation with adjunctive use of preserved amniotic membrane for surgical management of refractory glaucoma.Seven patients (5 female subjects) with refractory glaucoma were included in the study.
Heydar Amini +4 more
openaire +2 more sources
Interacción Fluido Estructura en una Microválvula para el Control de la Presión Intraocular [PDF]
Propósito: Evaluar el diseño de una microválvula utilizando métodos numéricos que permitan analizar geometrías complejas y la interacción entre el diafragma y el fluido.
Guarnieri, Fabio Ariel +1 more
core
Limbal reconstruction in uveitic glaucoma patient with exposed Ahmed valve coincident with corneal melting and iris prolapse using multiple corneoscleral allografts [PDF]
Stylianos Kandarakis +5 more
openalex +1 more source
Trabectome Surgery Combined with Baerveldt Glaucoma Implantation Negates Tube Fenestration [PDF]
Purpose: To evaluate the efficacy and survival rates of the same session ab interno trabeculectomy with trabectome and Baerveldt glaucoma implant (BT) compared to Baerveldt implant alone (B).
Esfandiari, Hamed +5 more
core
Ocular Biometric and Corneal Biomechanical Changes Following Ahmed Glaucoma Valve Implantation in Neovascular Glaucoma [PDF]
Ali Azimi +5 more
openalex +1 more source

