Purpose — to determine the effect of fistulizing operations with Glautex drainage and Ahmed valve implantation in the cases with neovascular glaucoma within 3 years.Patients and methods.
M. M. Bikbov, I. I. Khusnitdinov
doaj +1 more source
Systematic Occlusion of Shunts: Control of Early Postoperative IOP and Hypotony-related Complications Following Glaucoma Shunt Surgery. [PDF]
OBJECTIVE: Evaluation of a protocol of total intraluminal occlusion of Baerveldt shunts and its effects on early postoperative intraocular pressure (IOP) control and hypotony-related complications.
Achache, F. +6 more
core +1 more source
Abstract Primary congenital glaucoma (PCG) is one of the leading causes of visual damage and blindness, severely affecting the quality of life of affected children. It is characterized by cupping of the optic disc and loss of ganglion cells due to elevated intraocular pressure. While most PCG patients exhibit epiphora, photophobia, and buphthalmos with
Oscar Francisco Chacon‐Camacho +13 more
wiley +1 more source
Disadvantages of drainage device for output of intraocular fluid in glaucoma [PDF]
Основною причиною ураження очного нерва при глаукомі є підвищений рівень внутрішньоочного тиску (ВОТ), що виникає через втрату функцій трабекулярної мережі ока, через яку виводиться внутрішньоочна рідина [1]. Послідовність лікування глаукоми залежить від
Tkachuk, A. +3 more
core
Mid‐term surgical success after transscleral ab interno glaucoma gel stent implantation
Abstract Purpose To investigate the surgical success and efficacy of XEN45 implantation (XEN45 μm, AbbVie Inc., USA) with and without combined cataract surgery up to the first 5 years. Methods In a prospective observational monocentric trial, 192 eyes of 157 patients with open‐angle glaucoma received either XEN45 implants only (solo surgery group) or ...
Markus Lenzhofer +9 more
wiley +1 more source
Experimental and numerical response of a passive glaucoma drainage device [PDF]
Glaucoma is the optic nerve damage often associated with an increased intraocular pressure that leads to progressive and irreversible loss of vision. The Ahmed valve is a passive device constructed from two opposed deformable silicone elastomers sheets ...
Garelli, Luciano +2 more
core
Surgical results of trabeculectomy and Ahmed valve implantation following a previous failed trabeculectomy in primary congenital glaucoma patients [PDF]
PURPOSE: To compare the surgical results of trabeculectomy and Ahmed glaucoma valve implantation after a previous failed trabeculectomy. METHODS: A retrospective comparative case series review was performed on 31 eye surgeries in 20 patients with primary
김찬윤 +3 more
core +1 more source
Correlations between corneal biomechanical properties measured with the ocular response analyzer and icare rebound tonometry [PDF]
Purpose: To investigate the biomechanical properties of the normal cornea, and correlate them with central and peripheral corneal thickness and age. Methods: Seventy-six right eyes of volunteers were measured with Ocular Response Analyzer (ORA), ICare ...
Fernandes, Paulo Rodrigues +4 more
core +1 more source
Droplet Laplace valve‐enabled glaucoma implant for intraocular pressure management
A novel droplet‐based valving concept, the droplet Laplace valve (DLV), a three‐dimensional printable moving‐parts‐free microvalve with customizable and consistent threshold valving pressures, has been proposed for effective intraocular pressure management in glaucoma implants. The DLV uses a flow discretization unit comprising a droplet‐forming nozzle
Yuyang Wang +6 more
wiley +1 more source
Congenital ectopia lentis : diagnosis and treatment [PDF]
Congenital ectopia lentis (EL) is an ocular condition, which typically causes a high grade of refractive errors, mainly myopia and astigmatism. These might be difficult to compensate for, especially in children, who might develop ametropic amblyopia ...
Rysä Konradsen, Tiina
core +1 more source