Results 81 to 90 of about 5,657 (265)
Longer-term Baerveldt to Trabectome glaucoma surgery comparison using propensity score matching [PDF]
Purpose: To apply propensity score matching to compare Baerveldt glaucoma drainage implant (BGI) to Trabectome-mediated ab interno trabeculectomy (AIT). Recent data suggests that AIT can produce results similar to BGI which is traditionally reserved for ...
Brown, EN +6 more
core +1 more source
Abstract Primary congenital glaucoma (PCG) is one of the leading causes of visual damage and blindness, severely affecting the quality of life of affected children. It is characterized by cupping of the optic disc and loss of ganglion cells due to elevated intraocular pressure. While most PCG patients exhibit epiphora, photophobia, and buphthalmos with
Oscar Francisco Chacon‐Camacho +13 more
wiley +1 more source
Purpose — to determine the effect of fistulizing operations with Glautex drainage and Ahmed valve implantation in the cases with neovascular glaucoma within 3 years.Patients and methods.
M. M. Bikbov, I. I. Khusnitdinov
doaj +1 more source
Experimental and numerical response of a passive glaucoma drainage device [PDF]
Glaucoma is the optic nerve damage often associated with an increased intraocular pressure that leads to progressive and irreversible loss of vision. The Ahmed valve is a passive device constructed from two opposed deformable silicone elastomers sheets ...
Garelli, Luciano +2 more
core
Mid‐term surgical success after transscleral ab interno glaucoma gel stent implantation
Abstract Purpose To investigate the surgical success and efficacy of XEN45 implantation (XEN45 μm, AbbVie Inc., USA) with and without combined cataract surgery up to the first 5 years. Methods In a prospective observational monocentric trial, 192 eyes of 157 patients with open‐angle glaucoma received either XEN45 implants only (solo surgery group) or ...
Markus Lenzhofer +9 more
wiley +1 more source
Congenital ectopia lentis : diagnosis and treatment [PDF]
Congenital ectopia lentis (EL) is an ocular condition, which typically causes a high grade of refractive errors, mainly myopia and astigmatism. These might be difficult to compensate for, especially in children, who might develop ametropic amblyopia ...
Rysä Konradsen, Tiina
core +1 more source
Droplet Laplace valve‐enabled glaucoma implant for intraocular pressure management
A novel droplet‐based valving concept, the droplet Laplace valve (DLV), a three‐dimensional printable moving‐parts‐free microvalve with customizable and consistent threshold valving pressures, has been proposed for effective intraocular pressure management in glaucoma implants. The DLV uses a flow discretization unit comprising a droplet‐forming nozzle
Yuyang Wang +6 more
wiley +1 more source
This case concerns a young monoocular man with advanced glaucoma and twice explanted Ahmed Glaucoma Valve. A combined trabeculectomy with non-valved glaucoma drainage device implantation was performed, using a novel approach underneath a single shared ...
Arnav Panigrahi +3 more
doaj +1 more source
Surgical results of trabeculectomy and Ahmed valve implantation following a previous failed trabeculectomy in primary congenital glaucoma patients [PDF]
PURPOSE: To compare the surgical results of trabeculectomy and Ahmed glaucoma valve implantation after a previous failed trabeculectomy. METHODS: A retrospective comparative case series review was performed on 31 eye surgeries in 20 patients with primary
김찬윤 +3 more
core +1 more source
How latanoprost changed glaucoma management
Abstract Glaucoma is currently considered one of the leading causes of severe visual impairment and blindness worldwide. Topical medical therapy represents the treatment of choice for many glaucoma patients. Introduction of latanoprost, 25 years ago, with an entirely new mechanism of action from that of the antiglaucoma drugs used up to that time was a
Maria Francesca Cordeiro +4 more
wiley +1 more source