A Comparison of Performance of Endotracheal Intubation Using the Levitan FPS Optical Stylet or Lary‐Flex Videolaryngoscope in Morbidly Obese Patients

open access: yesThe Scientific World Journal, Volume 2014, Issue 1, 2014., 2014
Introduction. The use of videolaryngoscopes is recommended for morbidly obese patients. The aim of the study was to evaluate the Levitan FPS optical stylet (Levitan) vs Lafy‐Flex videolaryngoscope (Lary‐Flex) in a group of MO patients. Methods. Seventy‐nine MO (BMI > 40 kg m−2) patients scheduled for bariatric surgery were included in the study and ...
Tomasz Gaszynski   +4 more
wiley   +1 more source

INTUBACI 3N OROTRAQUEAL CON AIRTRAQ VERSUS LARINGOSCOPIA CONVENCIONAL EN PACIENTES CON OBESIDAD TIPO I PROGRAMADOS PARA CIRUG\ucdA ELECTIVA. [PDF]

open access: yes, 2014
El presente estudio tuvo como objetivo comparar la eficacia de la intubaci\uf3n orotraqueal con laringoscopia Airtraq versus laringoscopia convencional en pacientes con obesidad tipo I programados para cirug\ueda electiva.
Meza R., Roccio
core  

Difficult airway management resources and capnography use in Japanese intensive care units: a nationwide cross-sectional study [PDF]

open access: yes, 2016
PURPOSE: The availability of difficult airway management (DAM) resources and the extent of capnometry use in Japanese intensive care units (ICUs) remained unclear. The purpose of this study was to clarify whether: (1) DAM resources were adequate, and (2)
Inokuchi, Ryota   +15 more
core   +1 more source

Oral Injury Caused by the Airtraq®

open access: yesTHE JOURNAL OF JAPAN SOCIETY FOR CLINICAL ANESTHESIA, 2009
エアトラック®を用いた挿管で口腔内裂傷を起こした1例を経験した. 挿管を行ったのはエアトラック®の使用経験が20例以上ある麻酔科指導医であった. 挿管操作は円滑であったにもかかわらず, 右口蓋弓の裂傷は長さ3cm, 深さ1cmに及び縫合が必要であった. エアトラック®のブレード先端部分に丸みがなく鋭利であることが原因と考えたが, 2008年1月現在, 製造元ではブレードの仕様変更の予定はない. 当院では当面の安全対策として, シリコン製のカバーを先端部分に装着し先端部分を鈍にして使用している. また, エアトラック®の挿入方法についても再検討し, 推奨されている正中挿入法を遵守するよう心がけている.
Masayoshi SATO   +3 more
openaire   +2 more sources

Endotracheal Intubation Using the Macintosh Laryngoscope or KingVision Video Laryngoscope during Uninterrupted Chest Compression

open access: yesBioMed Research International, Volume 2014, Issue 1, 2014., 2014
Objective. Advanced airway management, endotracheal intubation (ETI), during CPR is more difficult than, for example, during anesthesia. However, new devices such as video laryngoscopes should help in such circumstances. The aim of this study was to assess the performance of the KingVision video laryngoscopes in a manikin cardiopulmonary resuscitation (
Ewelina Gaszynska   +2 more
wiley   +1 more source

COMPARATIVE EVALUATION OF AIRTRAQ OPTICAL LARYNGOSCOPE AND HUGE MED VIDEO LARYNGOSCOPE FOR LARYNGEAL VISUALISATION AND ENDOTRACHEAL INTUBATION IN ADULTS WITH ANTICIPATED DIFFICULT INTUBATION

open access: yesInternational Journal of Advanced Research, 2022
Background and Aims: Complications arising from difficult or failed tracheal intubation still remains a leading cause of anaesthetic morbidity and mortality.This has lead to development of multiple novel laryngoscopes.
Lalit Kumar Raiger   +3 more
semanticscholar   +1 more source

Changes in practice in managing difficult intubation following the introduction of new airway devices [PDF]

open access: yes, 2011
Introduction Difficult or failed tracheal intubation is a leading cause of anesthesia-related mortality and morbidity, ranging from soft tissue airway trauma to severe hypoxemia [1-3].
GUARNERO, V.
core  

A comparative study of endotracheal intubation as per intubation difficulty score, using Airtraq and McCoy laryngoscopes with manual-in-line axial stabilization of cervical spine in adult patients [PDF]

open access: yes, 2016
Background: The different types of laryngoscopes have been invented to improve the laryngoscopic view of the glottis in normal and difficult airway which helps anaesthesiologists to safeguard the airway during anaesthesia.
Sarvaiya, Nilesh   +2 more
core   +3 more sources

Airway Adventures of Airtraq: Use of Airtraq Optical Laryngoscope with Adaptor in Infants with Obstructive Hydrocephalus Posted for Endoscopic Third Ventriculostomy

open access: yesJournal of Neuroanaesthesiology and Critical Care, 2020
The pediatric airway is a challenge for the anesthetist due to difficulty in adequate assessment, scarcity of management algorithms, lack of precise knowledge regarding incidence, as well as limitations of the various devices, instruments, and video ...
Shahna Ali   +3 more
doaj   +1 more source

Out-of-hospital endotracheal intubation experience, confidence and confidence-associated factors among Northern Japanese emergency life-saving technicians: a population-based cross-sectional study [PDF]

open access: yes, 2018
OBJECTIVE: Clinical procedural experience and confidence are both important when performing complex medical procedures. Since out-of-hospital endotracheal intubation (ETI) is a complex intervention, we sought to clarify clinical ETI experience among ...
Iseki, Ken   +8 more