Results 151 to 160 of about 5,009,966 (344)

Enhanced analysis of gating latency in 0.35T MR‐linac through innovative time synchronization of a motion phantom and plastic scintillation detector

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study aims to evaluate how different gantry angles, breathing rates (BPM), cine image speeds, and tracking algorithms affect beam on/off latency and the subsequent impact on target dose for a 0.35T MR‐Linac with a 6 MV FFF beam.
Mateb Al Khalifa   +4 more
wiley   +1 more source

Automated rapidplan model validation using Eclipse scripting API

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract RapidPlan offers efficiency gains and quality improvements in treatment planning. Prior to its use in the clinic, it requires an extensive validation procedure in which established clinical plans and those generated by the model are compared. The manual iterative nature of this process is resource intensive, as numerous iterations are required
Bradley Beeksma   +2 more
wiley   +1 more source

Explainable representation learning of small quantum states

open access: yesMachine Learning: Science and Technology
Unsupervised machine learning models build an internal representation of their training data without the need for explicit human guidance or feature engineering.
Felix Frohnert, Evert van Nieuwenburg
doaj   +1 more source

UR‐cycleGAN: Denoising full‐body low‐dose PET images using cycle‐consistent Generative Adversarial Networks

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study aims to develop a CycleGAN based denoising model to enhance the quality of low‐dose PET (LDPET) images, making them as close as possible to standard‐dose PET (SDPET) images. Methods Using a Philips Vereos PET/CT system, whole‐body PET images of fluorine‐18 fluorodeoxyglucose (18F‐FDG) were acquired from 37 patients to ...
Yang Liu, ZhiWu Sun, HaoJia Liu
wiley   +1 more source

Beam model development and clinical experience with RadCalc for treatment plan quality assurance in online adaptive workflow with an MR‐linac

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose The aim of this work was to report on the optimization, commissioning, and validation of a beam model using a commercial independent dose verification software RadCalc version 7.2 (Lifeline Software Inc, Tyler, TX, USA), along with 4 years of experience employing RadCalc for offline and online monitor unit (MU) verification on the ...
Urszula Jelen   +3 more
wiley   +1 more source

Demonstration of an enhanced dosing pattern for debulking large and bulky unresectable tumors via differential hole‐size spatially fractionated radiotherapy

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose/objective We propose a novel lattice deployment for spatially fractionated radiotherapy (SFRT) treatments. In this approach, a larger diameter high‐dose sphere is centrally placed in the bulky tumor mass and surrounded by smaller diameter high‐dose spheres.
Joshua Misa   +2 more
wiley   +1 more source