Results 261 to 270 of about 857,388 (287)
Some of the next articles are maybe not open access.
TheoH and allan deviation as power-law noise estimators
IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 2007A spectral interpretation using the frequency sensitivity of the Allan variance (Avar) and Thêo-Hybrid (ThêoH) is used to determine falpha noise, or "power-law noise." ThêoH has narrower chi-square confidence than Avar; consequently, ThêoH provides significantly better determination of falpha noise types at long term.
Jennifer A, McGee, David A, Howe
openaire +2 more sources
About the stochastic features during intracranial pressure transients – the Allan deviation
2021Objective: The Allan deviation (AD) has not been generally used as a tool to determine the statistical properties of intracranial pressure (ICP) up to now. This fact is remarkable because concordance to modern analytic methods applied to ICP (i.e., the wavelet variance) exists. AD becomes important [for full text, please go to the a.m. URL]
Heissler, HE +3 more
openaire +2 more sources
Implementation of the Real-Time Assessment of Dynamic Allan Deviation and Dynamic Time Deviation
2014 European Frequency and Time Forum (EFTF), 2014In the paper the realization of the methods enabling real-time computation of dynamic Allan deviation and dynamic time deviation is described. The idea of real-time analysis of timing signals using dynamic approach is described first. Then the main features of the algorithms enabling the analysis and their implementation are presented and discussed.
Michal Kasznia
exaly +2 more sources
Proceedings International Symposium on Parallel Architectures, Algorithms and Networks. I-SPAN 2000, 2000
Time and frequency characterization of precision clocks and oscillators is an important task in the maintenance of time and frequency standards. Recently, time domain signal characterization of clocks is generally preferred and several performance measures of clocks and oscillators are defined in ITU-T Recommendation G.810.
Mingfu Li, Hsin-Min Peng, Chia-Shu Liao
openaire +2 more sources
Time and frequency characterization of precision clocks and oscillators is an important task in the maintenance of time and frequency standards. Recently, time domain signal characterization of clocks is generally preferred and several performance measures of clocks and oscillators are defined in ITU-T Recommendation G.810.
Mingfu Li, Hsin-Min Peng, Chia-Shu Liao
openaire +2 more sources
Analysis of Sensors Noise Performance Using Allan Deviation
2019 IEEE XXVIII International Scientific Conference Electronics (ET), 2019The paper presents the noise analysis of different sensor types using Allan Variance (AV). Compared to the conventional variance that assesses the variation around the mean value of the aggregate data surveyed, AV estimates variations by averaging measurements for different periods.
Marin B Marinov +2 more
exaly +2 more sources
IEEE Geoscience and Remote Sensing Letters, 2015
Currently, the instrument sensitivity of sensors onboard weather satellites is quantified by computing the standard deviation of the measurements taken from their calibration targets. The standard deviation is valid for describing the spread of a statistical distribution of the measured values around its mean that is stable.
Xiaolei Zou, Fuzhong Weng, Miao Tian
exaly +3 more sources
Currently, the instrument sensitivity of sensors onboard weather satellites is quantified by computing the standard deviation of the measurements taken from their calibration targets. The standard deviation is valid for describing the spread of a statistical distribution of the measured values around its mean that is stable.
Xiaolei Zou, Fuzhong Weng, Miao Tian
exaly +3 more sources
Multi-Source Maximum Likelihood Modified Allan Deviation Estimation
2020 Joint Conference of the IEEE International Frequency Control Symposium and International Symposium on Applications of Ferroelectrics (IFCS-ISAF), 2020The familiar “tri-cornered hat” method is sometimes used to compute ensemble-relative ADEV values for each of three reference oscillators, superficially independent of any particular reference. When one of the three oscillators is distinctly more stable, the tri-cornered had algorithm tends to give a poor estimate – estimates of AVAR may be negative ...
openaire +1 more source
Single-chip surface micromachined integrated gyroscope with 50°/h Allan deviation
IEEE Journal of Solid-State Circuits, 2002The design principles of a mass-produced surface micromachined gyroscope are described. The device is integrated on a single 3 mm/spl times/3 mm chip with a 3-/spl mu/m BiCMOS process. It has a 4-/spl mu/m-thick polysilicon structure, 5-V 6-mA supply, 12.5-mV//spl deg//S sensitivity, 10 000:1 dynamic range, 30 000-gee shock survival, and -55/spl deg/C ...
John A. Geen +3 more
openaire +2 more sources
Cost-Effective Allan Deviation Measurement in SDRs Using Integrated ADC
2024 IEEE Radio and Wireless Symposium (RWS)Shengjian Chen +2 more
exaly +3 more sources
An Algorithm to Estimate the Power Spectral Density From Allan Deviation
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency ControlComplex architectures for wireless communications, digital electronics, and space-based navigation interlink several oscillator-based devices such as clocks, transponders, and synthesizers. Estimators characterizing their stability are critical for addressing the impact of random fluctuations (noise) on the overall system performance.
De Marchi, Fabrizio +3 more
openaire +2 more sources

