Results 11 to 20 of about 93,884 (203)
Measurements of the ambient dose equivalent rates around the Manyoni uranium deposit in Tanzania
In this study, pre-mining ambient gamma dose equivalent rates at 1 m above the ground were measured using a Gamma-Scout portable radiation survey meter at two sites, A and B, around the Manyoni uranium deposit in Tanzania.
Farida Lolila, Mohamed Mazunga
doaj +1 more source
Measurement of cosmic radiation exposure of aircraft crew at commercial aviation altitudes [PDF]
The measurement results of ambient dose equivalent rate in an aircraft, performed by a standard portable dosimeter, at a non-commercial flight Belgrade - Podgorica at altitudes up to 9000 meters, are shown.
Vujičić Vladimir M. +5 more
doaj +1 more source
The use of X-ray facilities in calibrating radiation measuring equipment in diagnostic radiology requires an exact knowledge of the radiation field.
Tanjim Siddiqua +5 more
doaj +1 more source
THE IN-SITU CALIBRATION METHOD FOR AMBIENT DOSE EQUIVALENT DOSEMETERS
Abstract Ambient dose equivalent dosemeters are widely distributed in nuclear facilities for routine continuous monitoring or nuclear accident emergency monitoring, they are inconvenient to be disassembled and sent to the metrology laboratory for calibration.
Fei Gao +3 more
openaire +2 more sources
Radiation Exposure in the Lower Atmosphere during Different Periods of Solar Activity
In recent years, there has been a huge increase in air travel, both for business and leisure. For this reason, entities such as the European Commission and the International Committee on Radiological Protection have provided several recommendations for ...
Anastasia Tezari +9 more
doaj +1 more source
Neutron dosimetry at workplaces of JC “Institute of Nuclear Materials”
If the neutron fields at personnel workplaces differ from the neutron fields in which individual dosimeters are verified, there is a possibility of additional errors in the assessment of such dosimetric quantities as ambient dose equivalent, individual ...
M. D. Pyshkina +7 more
doaj +1 more source
Measurements in the stray radiation field from a proton therapy pencil beam at energies 70 and 146 MeV were performed using microdosimetric tissue-equivalent proportional counters (TEPCs).
Linda Eliasson +5 more
doaj +1 more source
Model for Reconstruction of γ-Background during Liquid Atmospheric Precipitation
With regard to reconstructing the gamma background dose rate, existing models are either empirical with limited applicability or have many unknown input parameters, which complicates their application in practice.
Valentina Yakovleva +4 more
doaj +1 more source
EVALUATION OF AMBIENT DOSE EQUIVALENT SURROUNDING TRANSMISSION FULL-BODY SCANNERS
Abstract This study analyses the ambient dose equivalent around transmission full-body scanners used in Brazilian prisons and airports. In order to achieve this goal, three transmission full-body scanners of the same model assembled by a Brazilian manufacturer were evaluated.
Caio Caraciolo Rodrigues Elias +6 more
openaire +2 more sources
The neutron ambient dose equivalent induced by galactic cosmic-ray-like (1 GeV/u 56Fe) radiation stopped in a thick aluminum shield was measured at different angles with a GSI neutron ball, the standard TLD (thermoluminescent dosimeters)-based neutron ...
Daria Boscolo +15 more
doaj +1 more source

