Results 211 to 220 of about 3,298,659 (298)

Variability elements of Poplar leaf anatomic structure

open access: yesMatica Srpska Proceedings for Natural Sciences, 1994
Orlović, Saša   +2 more
openaire  

High‐Density Magnetomyography With Optical Magnetometers Reveals Spatiotemporal Patterns of Evoked Muscle Activity

open access: yesAdvanced Materials Technologies, EarlyView.
Optically pumped magnetometers are employed to contactlessly map the spatiotemporal dynamics of the magnetic field linked to electrical activity of a skeletal muscle in vivo. It is demonstrated that localization of the clinically relevant innervation zone is feasible using this non‐invasive magnetic measurement modality. ABSTRACT Magnetomyography (MMG)
Simon Nordenström   +12 more
wiley   +1 more source

Autonomous Reconfigurable Modular Conductive Hydrogels for Adaptive and Degradable Bioelectronic Interfaces

open access: yesAdvanced Materials Technologies, EarlyView.
Bridging rigid electrodes with soft, irregular tissues demands more than conductivity alone. Modular conductive hydrogels autonomously reconfigure into conformal electrode‐tissue interfaces, coupling mixed ionic‐electronic conduction with tissue‐like mechanics, self‐healing, and degradability.
Matthew K. Burgess   +4 more
wiley   +1 more source

Development of a standardized documentation template for neck ultrasonography in oral and maxillofacial surgery: a technical note. [PDF]

open access: yesJ Korean Assoc Oral Maxillofac Surg
Kong UH   +7 more
europepmc   +1 more source

Self‐Sealing Microneedles Improve Precision and Reduce Reflux in Subretinal Cell Transplantation

open access: yesAdvanced Materials Technologies, EarlyView.
Ultrafine 49G microneedles enable subretinal delivery of induced pluripotent stem cell‐derived retinal pigment epithelial cells through a 50 µm outer diameter tip. Compared with conventional 38G microcannulas, these microneedles reduce cell suspension reflux in a rabbit model, highlighting the potential of microinvasive delivery instruments to improve ...
Jared Ching   +9 more
wiley   +1 more source

Position-Dependent Hemodynamics of Popliteal Artery Stent Grafts: The POPFLEX Study. [PDF]

open access: yesMethods Protoc
Chronis C   +5 more
europepmc   +1 more source

Soft Robotic Excretory Care Simulator for Nursing Education: Functional and Perceptual Biomimetics Approach

open access: yesAdvanced Robotics Research, EarlyView.
A soft robotic simulator is developed to replicate the digital removal of feces (DRF), a sensitive yet essential nursing procedure. Integrating soft actuators, sensors, and a realistic rectal model, the simulator balances functional fidelity with perceptual realism. Engineering evaluations and nurse feedback confirm its potential to enhance training in
Shoko Miyagawa   +10 more
wiley   +1 more source

Home - About - Disclaimer - Privacy