Results 31 to 40 of about 16,229 (219)

Accuracy of diagnostic codes and algorithms used to identify rheumatoid arthritis and juvenile idiopathic arthritis in administrative claims and electronic health records: systematic review and meta‐analysis.

open access: yesArthritis Care &Research, Accepted Article.
Objective This systematic review aimed to assess the diagnostic accuracy of algorithms used to identify rheumatoid arthritis (RA) and juvenile idiopathic arthritis (JIA) in electronic health records (EHRs). Methods We searched MEDLINE, Embase, and CENTRAL databases and included studies that validated case definitions against a reference standard such ...
Constanza Saka‐Herrán   +10 more
wiley   +1 more source

Raquianestesia contínua em paciente submetido à gastrectomia parcial: relato de caso Raquianestesia continua en paciente sometido a la gastrectomía parcial: relato de caso Continuous spinal block in a patient undergoing partial gastrectomy: case report

open access: yesRevista Brasileira de Anestesiologia, 2009
JUSTIFICATIVA E OBJETIVOS: Devido à alta incidência de complicações técnicas e neurológicas, a raquianestesia contínua foi abandonada por muitos anos. Com o surgimento dos cateteres intermediários, a técnica vem ressurgindo e ganhando simpatia no arsenal
Patrícia Falcão Pitombo   +2 more
doaj   +1 more source

Ultra sound guided erector spinae plane block for perioperative analgesia in post coronary artery bypass grafting sternal dehiscence (Type 2b) patient posted for pectoralis major flap

open access: yesCHRISMED Journal of Health and Research, 2021
Sternal dehiscence is a grave complication after cardiac surgery. Deep sternal dehiscence usually requires debridement and flap coverage as the mainstay of management.
Bhimala Naga Ramya   +3 more
doaj   +1 more source

Transducer Materials Mediated Deep Brain Stimulation in Neurological Disorders

open access: yesAdvanced Functional Materials, EarlyView.
This review discusses advanced transducer materials for improving deep brain stimulation (DBS) in neurological disorders. These materials respond to light, ultrasound, or magnetic fields, enabling precise, less invasive neuromodulation. Their stimulus‐responsive properties enhance neural control and adaptive therapy, paving the way for next‐generation ...
Di Zhao   +5 more
wiley   +1 more source

Avaliação da bupivacaína hipobárica a 0,5% na raquianestesia Evaluación de la bupivacaína hipobárica a 0,5% en la anestesia espinal Evaluation of 0.5% hypobaric bupivacaine in spinal anesthesia

open access: yesRevista Brasileira de Anestesiologia, 2007
JUSTIFICATIVA E OBJETIVOS: A raquianestesia causa alterações hemodinâmicas relacionadas com fatores próprios do paciente ou não. Um dos fatores é a densidade do anestésico em relação ao líquor, interferindo no número de dermátomos bloqueados e ...
Marcelo Cursino Pinto dos Santos   +3 more
doaj   +1 more source

Calcium Imparts Advanced Functionalities to Silk Hydrogels for Biofabrication and Biomedical Innovation

open access: yesAdvanced Functional Materials, EarlyView.
The addition of calcium ions to silk fibroin enhances the hydrogel properties and, when combined with visible light crosslinking, enables compatibility with advanced light‐based fabrication techniques. Calcium ions extend the shelf‐life of silk and facilitate the fabrication of multizonal, multilayered constructs for advanced stimuli‐responsive ...
Hien A. Tran   +11 more
wiley   +1 more source

Mistura com excesso enantiomérico de 50% de bupivacaína (S75:R25) hiperbárica para procedimentos cirúrgicos infra-umbilicais: estudo com diferentes volumes Mezcla con exceso enantiomérico de 50% de bupivacaína (S75:R25) hiperbárica para procedimientos quirúrgicos infraumbilicales: estudio con diferentes volúmenes 50% enantiomeric excess hyperbaric bupivacaine (S75:R25) for infraumbilical surgeries: study with different volumes

open access: yesRevista Brasileira de Anestesiologia, 2009
JUSTIFICATIVA E OBJETIVOS: A bupivacaína hiperbárica comercialmente utilizada apresenta-se como forma racêmica. No Brasil, a bupivacaína em excesso enantiomérico de 50% (S75:R25) foi lançada somente na forma isobárica. O objetivo deste estudo foi avaliar
Luiz Eduardo Imbelloni   +1 more
doaj   +1 more source

Body Biofluids for Minimally‐Invasive Diagnostics: Insights, Challenges, Emerging Technologies, and Clinical Potential

open access: yesAdvanced Healthcare Materials, EarlyView.
Recent advances in diagnostics have accelerated the development of miniaturized wearable technologies for the continuous monitoring of diseases. This paradigm is shifting healthcare away from invasive, centralized blood tests toward decentralized monitoring, using alternative body biofluids.
Lanka Tata Rao   +2 more
wiley   +1 more source

Meningite após técnica combinada para analgesia de parto: relato de caso Meningitis después de técnica combinada para analgesia de parto: relato de caso Meningitis after combined spinal-epidural analgesia for labor: case report

open access: yesRevista Brasileira de Anestesiologia, 2002
JUSTIFICATIVA E OBJETIVOS: Meningite é uma complicação grave em anestesia regional, embora rara de ocorrer. O objetivo deste relato é mostrar um caso de uma paciente que evoluiu com meningite após realização de analgesia de parto pela técnica combinada ...
Carlos Escobar Vásquez   +4 more
doaj   +1 more source

Smart Catheters for Diagnosis, Monitoring, and Therapy

open access: yesAdvanced Healthcare Materials, EarlyView.
This study presents a comprehensive review of smart catheters, an emerging class of medical devices that integrate embedded sensors, robotics, and communication systems, offering increased functionality and complexity to enable real‐time health monitoring, diagnostics, and treatment. Abstract This review explores smart catheters as an emerging class of
Azra Yaprak Tarman   +12 more
wiley   +1 more source

Home - About - Disclaimer - Privacy