Results 61 to 70 of about 58,144 (239)
Purpose: To determine the efficacy of balloon angioplasty with long (80-210 mm) and short (less than 60mm) balloons in group of patients with critical limb ischemia.Materials and Methods: Short-term results of balloon angioplasty of 130 patients was ...
I. I. Katelnitskiy+2 more
doaj +1 more source
ABSTRACT Background Clinical studies have demonstrated the safety and effectiveness of drug‐coated balloon (DCB) angioplasty for femoropopliteal revascularization. Long‐term studies in routine practice are limited. Aims The aim of this study was to assess long‐term outcomes after DCB angioplasty for femoropopliteal peripheral artery disease in a real ...
Yann Gouëffic+4 more
wiley +1 more source
Background A retrospective study of 44 patients with autologous arteriovenous fistula (AVF) presenting with cephalic arch stenosis was carried out. The aim is to assess the effectiveness of angioplasty and stenting in cephalic arch stenosis in autologous
Hassan Abdelsalam
doaj +1 more source
ABSTRACT Background Stent underexpansion significantly heightens the risk of major adverse cardiac events (MACE), and available treatment options for this condition remain limited. Intravascular Lithotripsy (IVL) technology disrupts superficial and deep calcium by using localized pulsative sonic pressure waves, emerges as a promising tool for ...
Marios Sagris+9 more
wiley +1 more source
Feasibility and performance of a device for automatic self-detection of symptomatic acute coronary artery occlusion in outpatients with coronary artery disease : a multicentre observational study [PDF]
Background Time delay between onset of symptoms and seeking medical attention is a major determinant of mortality and morbidity in patients with acute coronary artery occlusion. Response time might be reduced by reliable self-detection.
Coeman, Mathieu+11 more
core +2 more sources
Background The superiority of balloon angioplasty plus aggressive medical management (AMM) to AMM alone for symptomatic intracranial artery stenosis (sICAS) on efficacy and safety profiles still lacks evidence from randomised controlled trials (RCTs).Aim
Liping Liu+13 more
doaj +1 more source
ABSTRACT Background Historically, bilateral pulmonary artery band (PAB) placement was guided by pulmonary blood flow surrogates including systemic blood pressure (BP) and arterial saturation. These metrics alone may result in suboptimal bPAB placement.
Jonathan Pacella+8 more
wiley +1 more source
Effects of balloon injury on neointimal hyperplasia in steptozotocin-induced diabetes and in hyperinsulinemic nondiabetic pancreatic islet-transplanted rats. [PDF]
BACKGROUND: The mechanisms of increased neointimal hyperplasia after coronary interventions in diabetic patients are still unknown. METHODS AND RESULTS: Glucose and insulin effects on in vitro vascular smooth muscle cell (VSMC) proliferation and ...
Carriero M.V.+13 more
core
Heme oxygenase-1 genotype and restenosis after balloon angioplasty: a novel vascular protective factor [PDF]
ObjectivesWe investigated the association of the heme oxygenase-1 (HO-1) promoter genotype with the inflammatory response and restenosis after balloon angioplasty.BackgroundHeme oxygenase-1, which is induced by balloon angioplasty, can inhibit neointima ...
Bach, Fritz H+7 more
core +1 more source
Background Percutaneous transluminal angioplasty is the current standard treatment for arteriovenous fistula (AVF) stenosis. The mid- and long-term patency with plain balloon angioplasty (PBA) is however far from satisfactory.
Suh Chien Pang+33 more
doaj +1 more source