Results 11 to 20 of about 458,876 (308)
Doppler angle correction in the measurement of intrarenal parameters [PDF]
Jing Gao¹, Keith Hentel¹, Qiang Zhu², Teng Ma², George Shih¹, Kevin Mennitt¹, Robert Min¹¹Department of Radiology, New York Presbyterian Hospital, Weill Cornell Medical College, NY ...
Mennitt K +6 more
doaj +1 more source
Internal rotator cuff muscles torque-angle-curves. [PDF]
Pre- (blue) and Post-measurement (red) torque-angle curves for 30°/s, 60°/s and 180°/s (top-to-bottom) for the eccentric (left column) and concentric (right column) strength.
Sebastian Vetter (4018448) +6 more
core +1 more source
External rotator cuff muscles torque-angle-curves. [PDF]
Pre- (blue) and Post-measurement (red) torque-angle curves for 30°/s, 60°/s and 180°/s (top-to-bottom) for the eccentric (left column) and concentric (right column) strength.
Sebastian Vetter (4018448) +6 more
core +1 more source
In this paper, a methodology is discussed concerning the measurement of yarn’s angle of two different glass-reinforced polypropylene matrix materials, widely used in the production of automotive components.
Giulio D’Emilia +3 more
doaj +1 more source
Measurements of curvilineal angles
The essential aim of this paper is to define a nontrivial measure for the angle between tangent curves. A directed ``curvilineal'' angle \(\alpha\) is a pair of curves in the Euclidean plane, emanating from the same vertex. A measure \(\varphi=\varphi(\varepsilon)\) of \(\alpha\) can be established in a geometric manner as follows: draw a (small ...
van Asch, A. G., van der Blij, F.
openaire +4 more sources
Reliability of popliteal angle measurement: a study in cerebral palsy patients and healthy controls [PDF]
The popliteal angle is a widely used clinical measure for hamstring contracture in cerebral palsy (CP) patients and in healthy individuals. The reliability of popliteal angle measurement is being questioned.
Pieter U. Dijkstra +17 more
core +1 more source
This paper proposed angle measurement methods based on direct third harmonic generation (THG) in centrosymmetric crystals. The principles of the intensity-dependent and the wavelength-dependent angle measurement methods were illustrated.
Kuangyi Li +6 more
doaj +1 more source
A Two-Axis Goniometric Sensor for Tracking Finger Motion
The study of finger kinematics has developed into an important research area. Various hand tracking systems are currently available; however, they all have limited functionality.
Lefan Wang +2 more
doaj +1 more source
Investigation of Sensor for Measurement of Rotation Angle of Sensitive Element in Rotational Paper Pulp Consistometer [PDF]
This paper presents the results of theoretical and experimental testing of an optical rotation angle sensor of rotational paper pulp consistency meter.
Yevhen Pistun +3 more
core +1 more source
A New Payload Swing Angle Sensing Device and Its Accuracy
Measuring the swing angle of a crane load is a relatively well-known but unsatisfactorily solved problem in technical practice. This measurement is necessary for the automatic stabilization of load swing without human intervention. This article describes
Patrik Grosinger +4 more
doaj +1 more source