Results 221 to 230 of about 171,290 (313)

Distal Upper Molar Force Distribution With Clear Aligners Using Different Anterior Teeth Anchorage Setups: A Finite Element Study

open access: yesOrthodontics &Craniofacial Research, EarlyView.
ABSTRACT Objective The notion that clear aligners alone can distalize upper molars without affecting anterior teeth is inaccurate. Although strategies such as Class II elastics, tooth‐movement sequencing, and attachment variations have been investigated to mitigate unwanted side effects, temporary anchorage devices have demonstrated potential for ...
Weber Jose da Silva Ursi   +4 more
wiley   +1 more source

Enhancing stroke risk stratification in atrial fibrillation through non‐Newtonian blood modelling and Gaussian process emulation

open access: yesThe Journal of Physiology, EarlyView.
Abstract figure legend Non‐Newtonian modelling and GPEs for stroke risk in atrial fibrilation patients. Abstract Atrial fibrillation (AF) is the most common heart arrhythmia, linked to a five‐fold increase in stroke risk. The left atrial appendage (LAA), prone to blood stasis, is a common thrombus formation site in AF patients.
Paolo Melidoro   +12 more
wiley   +1 more source

Virtual left atrial appendage occlusion in paroxysmal atrial fibrillation during sinus rhythm predicts variable reductions in blood stasis

open access: yesThe Journal of Physiology, EarlyView.
Abstract figure legend Stasis before and after left atrial appendage occlusion (LAAO) in participants with high stasis and low stasis. Stasis is predominantly located in LAA and reduced after LAAO. But in the participant with high stasis, stasis remains close to the occlusion site, indicating a potential risk for device related thrombi.
Sophia Bäck   +6 more
wiley   +1 more source

A rheological study of human cranial cavity in shirodhara procedure using finite element method. [PDF]

open access: yesJ Ayurveda Integr Med
Sivaselvi K   +4 more
europepmc   +1 more source

A Mathematical Model for Two‐Phase Flow in Confined Environments: Numerical Solution and Validation

open access: yesInternational Journal for Numerical Methods in Fluids, Volume 98, Issue 3, Page 306-320, March 2026.
We present a numerical framework based on the Cahn‐Hilliard‐Navier‐Stokes (CHNS) model to simulate biphasic flow in confined environments. After deriving the mathematical model, we develop the weak form of the system of PDEs using a pedagogical approach to enable its implementation in FEniCS.
Giuseppe Sciumè   +3 more
wiley   +1 more source

Biomechanical Analysis and Injury Prediction in Pilots With Lumbar Spondylolysis Under Different Seat Inclination Angles

open access: yesJOR SPINE, Volume 9, Issue 1, March 2026.
The biomechanical responses of three lumbar models under both seat angles remain below injury thresholds. However, the occurrence of spondylolysis at a 22° angle poses a higher risk. ABSTRACT Background This study aims to quantify the biomechanical effects of different seat inclinations on the normal and spondylolysis lumbar of pilots under typical ...
Mengmeng Jin   +5 more
wiley   +1 more source