Results 91 to 100 of about 44,802 (314)

Prevalence and Recovery of Arrhythmia‐Induced Cardiomyopathy in Patients With Newly Diagnosed Heart Failure Using a Wearable Defibrillator: A Real‐World Cohort Study

open access: yesJournal of Cardiovascular Electrophysiology, EarlyView.
This graphical abstract summarizes the study design and main findings in patients with newly diagnosed left ventricular systolic dysfunction and concomitant arrhythmia undergoing early rhythm control under wearable cardioverter‐defibrillator protection.
Joerg Yogarajah   +10 more
wiley   +1 more source

Comportamiento de la TSH y la T4 en una cohorte de pacientes con arritmia cardiaca tratados con amiodarona u otros antiarrítmicos Behavior of TSH and T4 in a cohort of patients with cardiac arrhythmia treated with amiodarone or other antiarrhythmics

open access: yesRevista Colombiana de Cardiología, 2008
La amiodarona es uno de los antiarrítmicos de uso más extendido, pero de la misma forma es un medicamento con efectos adversos bien conocidos y a múltiples niveles; uno de los más importantes es el que se describe para el tejido tiroideo. Cerca de 80% de
Erwing A Vargas   +4 more
doaj  

Proarrhythmic Antiarrhythmic [PDF]

open access: yesTexas Heart Institute Journal, 2016
Mark, Pollet, Mohammad, Saeed
openaire   +2 more sources

Mechanical Circulatory Support During Ventricular Tachycardia Ablation: A Systematic Review and Meta‐Analysis of Procedural and Clinical Outcomes

open access: yesJournal of Cardiovascular Electrophysiology, EarlyView.
ABSTRACT Catheter ablation is an established therapy for ventricular tachycardia (VT); however, hemodynamic instability frequently limits procedural mapping and success. Temporary mechanical circulatory support (tMCS) devices are increasingly used to maintain end‐organ perfusion during VT ablation, yet their impact on clinical outcomes remains ...
Ahmed Nazmy   +19 more
wiley   +1 more source

Comparison of Two Pulsed Field Ablation Systems for Atrial Fibrillation: One‐Year Outcomes From a Multicenter Registry

open access: yesJournal of Cardiovascular Electrophysiology, EarlyView.
ABSTRACT Background While various pulsed field ablation (PFA) systems for atrial fibrillation (AF) ablation have become available in recent years, data comparing long‐term efficacy outcomes remain limited. Purpose To compare long‐term efficacy outcomes of two commercially available PFA systems to perform pulmonary vein isolation (PVI) for AF in a ...
Marisa van der Graaf   +18 more
wiley   +1 more source

Bifunctional agents for reperfusion arrhythmias: Novel hybrid vitamin E/class I antiarrhythmics

open access: yes, 2003
We have synthesized a series of hybrid compounds combining the pharmacophoric redox moieties of vitamin E and key features responsible for the antiarrhythmic properties of the class I antiarrhythmics procainamide and lidocaine. Procainamide analogue (2a)
Chryselis, M.   +6 more
core  

Invasive Assessment of Right Ventricular Dysfunction Predicts Periprocedural Outcomes in Patients Undergoing Unplanned Ventricular Tachycardia Ablation

open access: yesJournal of Cardiovascular Electrophysiology, EarlyView.
Displays bar graphs showing outcome rates stratified by clinical and hemodynamic variables. Asterisks (*) denote statistically significant differences (p ≤ 0.05). “NS” indicates non‐significant comparisons. Percentages are shown above each bar. The top panel corresponds to acute kidney injury (blue bars), and the bottom panel corresponds to acute ...
Tess Calcagno   +23 more
wiley   +1 more source

Comparative Efficacy of Continuous Versus Patch ECG Monitoring in Detecting Atrial Fibrillation Recurrence Post Catheter Ablation: Insights From the REAL‐AF Registry

open access: yesJournal of Cardiovascular Electrophysiology, EarlyView.
ABSTRACT Background Effective monitoring of atrial fibrillation (AF) recurrence following catheter ablation is crucial for optimizing patient outcomes. Various monitoring strategies exist, but effectiveness comparisons remain underexplored. Objective This study compares the recurrence of atrial arrhythmias detected by continuous versus patch ECG ...
Chinmaya Mareddy   +24 more
wiley   +1 more source

Asian Pacific Association of Gastroenterology (APAGE) Clinical Practice Guidelines on the Use of Small Molecules and IL‐23 p19 Inhibitors in Ulcerative Colitis and Crohn's Disease

open access: yesJournal of Gastroenterology and Hepatology, EarlyView.
ABSTRACT Ulcerative colitis (UC) and Crohn's disease (CD) are increasingly prevalent in the Asia Pacific region, necessitating updated, region‐specific guidance on advanced therapies. Targeted small molecule agents, such as filgotinib, tofacitinib, upadacitinib, etrasimod, and ozanimod; and the IL‐23 p19 inhibitors (guselkumab, mirikizumab ...
Choon Jin Ooi   +34 more
wiley   +1 more source

Therapy for patient with atrial fibrillation: in search of a balance between efficacy and safety

open access: yesКлинический разбор в общей медицине
This paper analyzes aspects of the efficacy and safety of antiarrhythmic drugs in the treatment of atrial fibrillation. It considers drug-drug interactions of antiarrhythmics with other drugs, especially in the near circle, i.e.
Yakov G. Bozhko   +2 more
doaj   +1 more source

Home - About - Disclaimer - Privacy