Results 171 to 180 of about 2,303,622 (245)
Coronary Perforation During Excimer Laser Angioplasty in a Patient With Prior Thoracic Radiotherapy
ABSTRACT Background Management of heavily calcified coronary lesions remains challenging despite advances in plaque‐modifying technologies. Excimer laser coronary angioplasty (ELCA) is an effective adjunctive strategy with a low risk of no‐reflow. Case Summary A 75‐year‐old woman with non–ST‐segment elevation acute coronary syndrome and severe left ...
Francesco Maria Sparasci +3 more
wiley +1 more source
ABSTRACT Background Vascular access site complications (VASCs) remain an important source of morbidity following percutaneous interventions. Although the sheath‐to‐femoral artery ratio is a recognized risk factor in transcatheter aortic valve implantation (TAVI), its role across a broader range of femoral procedures is less well defined.
Eduardo Ismael Arteaga Chan +2 more
wiley +1 more source
ABSTRACT Introduction The prevalence of bioprosthetic aortic valve failure is increasing due to the broader use of bioprosthetic valves, both surgical and transcatheter, and an ageing population. Registry data indicate a higher risk of coronary obstruction and elevated gradients following valve‐in‐valve transcatheter aortic valve implantation (TAVI ...
Hilal Khan +14 more
wiley +1 more source
ABSTRACT Background Quantitative Flow Ratio (QFR) is a well‐established, non‐hyperemic, angiographic, wire‐free predictor of ischemia when compared to Fractional Flow Reserve (FFR). However, its diagnostic accuracy at low frame rates (< 10 frames/second), commonly used in contemporary practice to minimize radiation exposure, has not been evaluated ...
Joseph M. O'Brien +13 more
wiley +1 more source
Bridging the gaps: Insights from the 2024 ESC guidelines on peripheral arterial and aortic diseases
Fabio Massimo Oddi +4 more
doaj +1 more source
ABSTRACT Background Despite recommendations in international guidelines, Intracoronary pressure wire assessment (PWA) utilization remains limited in clinical practice. This study aims to describe (i) trends of PWA during Percutaneous coronary interventional (PCI), (ii) factors that predict its application, and (iii) association with in‐hospital ...
Hussein Bashar +3 more
wiley +1 more source
Physiology‐Guided Drug‐Coated Balloon Angioplasty: What We Know and What is Yet to be Understood
Catheterization and Cardiovascular Interventions, EarlyView.
Marco Frazzetto +4 more
wiley +1 more source
ABSTRACT Background Transcatheter aortic valve implantation (TAVI) with the Acurate Neo has been linked to a significant incidence of paravalvular leakage (PVL), addressed by the Acurate Neo 2 incorporating an active sealing skirt. Recent findings suggest that midframe under‐expansion is associated with worse outcomes.
Lisa Crusius +9 more
wiley +1 more source
ABSTRACT Background Transcatheter patent ductus arteriosus (PDA) device closure is an effective treatment option for premature infants with hemodynamically significant PDA. Left pulmonary artery (LPA) stenosis has been reported as a complication, however there is limited data on risk factors, clinical significance, and long‐term outcomes.
Bryan Mosher +7 more
wiley +1 more source
Clinical Impact of Adherence to Fractional Flow Reserve Guidance in Acute Coronary Syndrome
ABSTRACT Background Fractional flow reserve (FFR) is established to guide revascularization in stable coronary disease and non‐culprit lesions in acute coronary syndromes (ACS). However, real‐world adherence to FFR guidance across the spectrum of ACS presentations, including ambiguous culprit scenarios, remains incompletely characterized.
Eun Ho Choo +5 more
wiley +1 more source

