Results 41 to 50 of about 185,166 (167)
BackgroundFenestrated and/or branched endovascular aortic repair (f/bEVAR) has evolved a reliable alternative to treat complex aortic aneurysms. The aim of this study was to analyze the evolution of f/bEVAR in a large German vascular department by ...
Yannik Wanner +7 more
doaj +1 more source
Summary: Objective: To compare the outcomes of the en bloc and branched graft techniques for supra-aortic vessel reconstruction in total arch replacement (TAR) for acute type A aortic dissection (ATAAD).
Yi Lin +6 more
doaj +1 more source
Acute abdominal aortic occlusion associated with transient paraplegia
We describe a rare case of acute occlusion of the abdominal aorta presenting as a rapidly evolving flaccid paraplegia owing to spinal cord ischemia and our management protocol that allowed complete recovery of the patient.
Florent Porez, MD +5 more
doaj +1 more source
Addressing proximal complications that arise after endovascular aortic repair for type B aortic dissection, such as type Ia endoleaks, “bird-beaking” of the thoracic endovascular aortic repair (TEVAR) stent, retrograde type A dissection, and ...
Caroline Radner, MD +6 more
doaj +1 more source
Safety and effectiveness of the sutureless integrated stented graft prosthesis in an animal model
Background: Prolonged circulatory arrest time is an independent risk factor for postoperative adverse events of type A aortic dissection (TAAD) surgery. Further reduction of the circulatory arrest time is essential to improve surgical outcomes.
Lu Dai +9 more
doaj +1 more source
Inferior vena cava atresia is a rare and usually asymptomatic condition. However, when these patients undergo cardiac surgery, it can present an unexpected and challenging situation for the surgeon.
Joscha Buech +16 more
doaj +1 more source
Accuracy of the HeartMate 3 Left Ventricular Assist Device Flow Estimation
Left ventricular assist devices (LVADs), such as the HeartMate 3 (HM3), are a treatment option for advanced heart failure (HF). Non-invasive monitoring of heart-pump interaction is crucial but relies on estimated parameters only.
Theodor Abart +6 more
doaj +1 more source
Impact of adjustable resistance clamps on the in-vitro hemolysis assessment of blood pumps
Adjustable resistance clamps are essential to regulate flow and pressure in in-vitro test loops designed to evaluate hemolysis in blood pumps. However, their contribution to overall hemolysis remains unclear.
Krishnaraj Narayanaswamy +6 more
doaj +1 more source