Results 121 to 130 of about 525,140 (261)
E. Murat Tuzcu of Cleveland Clinic Abu Dhabi in the United Arab Emirates and Ourania Preventza of Baylor College of Medicine in Houston, Texas, discuss valve-in-valve transcatheter aortic valve replacement versus redo surgical aortic valve replacement ...
Ourania Preventza (5175572) +1 more
core +1 more source
Gutter Rotation Technique for Percutaneous Ipsilateral Retrieval of a Ruptured SAPIEN‐3 Balloon
ABSTRACT Balloon rupture during transcatheter aortic valve replacement (TAVR) with balloon‐expandable valves is a rare but potentially serious complication that may result in incomplete valve expansion, difficult device retrieval, and vascular injury.
Anne Venkata Ganeshkumar +5 more
wiley +1 more source
Objective: The study objective was to evaluate outcomes after aortic valve replacement in patients with large or extra-large annuli. Methods: We conducted a retrospective cohort study of adults undergoing isolated transcatheter aortic valve replacement ...
Xander Jacquemyn, MD +11 more
doaj +1 more source
ABSTRACT Background Acquired aseptic intracardiac communications (AICCs) are rare but clinically relevant structural complications following transcatheter aortic valve implantation (TAVI), typically resulting from mechanical injury to the aortic annulus, interventricular septum, or adjacent structures.
Geza Fontos +6 more
wiley +1 more source
Atrioventricular conduction abnormalities (AVCA) may complicate transcatheter aortic valve implantation (TAVI) and surgical aortic valve replacement (SAVR).
Windecker, Stephan +20 more
core +1 more source
Early Experience With Evoque Transcatheter Tricuspid Valve Replacement in Carcinoid Heart Disease
ABSTRACT Tricuspid regurgitation (TR) is nearly universal in carcinoid heart disease (CHD), but surgical replacement carries significant risk, and CHD was excluded from the landmark TRISCEND II trial. We present seven patients with CHD undergoing Evoque transcatheter tricuspid valve replacement (TTVR) at two tertiary centers.
Jackson S. Burton +3 more
wiley +1 more source
ABSTRACT Background RFR has shown good aggregate agreement with FFR, including in prior Asian cohorts using intracoronary nicorandil. Where RFR‐FFR disagreement is concentrated relative to the FFR 0.80 decision boundary, and how the two binary thresholds correspond, remain incompletely characterized. Methods In a prospective single‐center registry, 300
Yonghoon Shin +8 more
wiley +1 more source
ABSTRACT The SAPIEN M3 system has been recently approved for transcatheter mitral valve replacement (TMVR). The transeptal guide sheath is used to deploy the dock, which is completely released before inserting and deploying the M3 valve using the same femoral access, transeptal puncture (TSP) and guide sheath.
Clara Fernandez‐Cordon +5 more
wiley +1 more source
Aortic root replacement for bicuspid aortic valve dysfunction does not impair survival rates
Background Patients with a bicuspid aortic valve carry an increased risk for developing an ascending aortic aneurysm due to intrinsic aortic wall alterations.
Onur B. Dolmaci +4 more
doaj +1 more source
The Triple Wire Dual Angioseal Technique for Large Bore Femoral Access Closure
ABSTRACT There is a growing need for large‐bore femoral access across cardiac interventions. This has led to a need for more widely accessible vascular closure techniques to facilitate reliable vascular closure and wider access to these interventions.
Hilal Khan, Mohaned Egred
wiley +1 more source

