Comparison between dynamic contour tonometry and Goldmann applanation tonometry correcting equations [PDF]
In order to investigate the reliability of correcting GAT formulas in comparison with dynamic contour tonometry (DCT), this study included 112 right eyes of 112 healthy subjects aged from 21 to 77 years, whose eyes underwent to a full ophthalmologic exam.
Maddalena De Bernardo +5 more
doaj +3 more sources
Accuracy of dynamic contour tonometry, Goldmann applanation tonometry, and Tono-Pen XL in edematous corneas [PDF]
Purpose: To investigate in vitro the accuracy of dynamic contour tonometry, Goldmann applanation tonometry, and Tono-Pen XL in edematous corneas. Methods: Experimental study included 20 freshly enucleated porcine eyes.
George A. Kontadakis +5 more
doaj +3 more sources
Comparison of rebound tonometry and non-contact airpuff tonometry to Goldmann applanation tonometry [PDF]
Purpose: The aim of this study was to compare the intraocular pressure measurements obtained from healthy subjects with the rebound tonometry, non-contact airpuff tonometry, and Goldmann applanation tonometry in different age groups.
Goktug Demirci +4 more
doaj +3 more sources
Agreement of rebound and applanation tonometry intraocular pressure measurements during atmospheric pressure change. [PDF]
This study investigated the agreement of intraocular pressure measurements using rebound tonometry and applanation tonometry in response to atmospheric changes in a hyperbaric chamber. Twelve eyes of 12 healthy subjects were included in this prospective,
Alice Verticchio Vercellin +7 more
doaj +3 more sources
Using Deep Learning to Automate Goldmann Applanation Tonometry Readings. [PDF]
PURPOSE To develop an objective and automated method for measuring intraocular pressure using deep learning and fixed-force Goldmann applanation tonometry (GAT) techniques.
Spaide T +9 more
europepmc +2 more sources
Reliability of Intraocular Pressure Measurement by Goldmann Applanation Tonometry After Refractive Surgery: A Review of Different Correction Formulas. [PDF]
Myopia is one of the main risk factors for the onset of open-angle glaucoma. One of the first steps to assess glaucoma occurrence is the measurement of the intraocular pressure (IOP) by the Goldmann applanation tonometry (GAT).
De Bernardo M, Cembalo G, Rosa N.
europepmc +2 more sources
The Association of Central Corneal Thickness and Intraocular Pressure Measures by Non-Contact Tonometry and Goldmann Applanation Tonometry among Glaucoma Patients. [PDF]
Background The aim of this study was to determine whether Central Corneal Thickness (CCT) is associated with intraocular pressure measurement (IOP) with a Non-contact tonometer and the Goldmann applanation tonometer in glaucoma patients.
Kyei S +3 more
europepmc +2 more sources
Evaluation of arterial stiffness in cardiac surgical patients using applanation tonometry [PDF]
Context: Applanation tonometry enables the noninvasive analysis of arterial pressure wave morphology. Applanation tonometry provides the augmentation index (AIx, %), an index of arterial stiffness that partially reflects arterial-ventricular (A-V ...
Federico Franchi +7 more
doaj +2 more sources
Brachial Blood Pressure Invasively and Non-Invasively Obtained Using Oscillometry and Applanation Tonometry: Impact of Mean Blood Pressure Equations and Calibration Schemes on Agreement Levels [PDF]
The use of oscillometric methods to determine brachial blood pressure (bBP) can lead to a systematic underestimation of the invasively measured systolic (bSBP) and pulse (bPP) pressure levels, together with a significant overestimation of diastolic ...
Daniel Bia +8 more
doaj +2 more sources
Comparability of three intraocular pressure measurement: iCare pro rebound, non-contact and Goldmann applanation tonometry in different IOP group. [PDF]
BackgroundMeasurement of intraocular pressure (IOP) is essential for glaucoma patients. Many factors such as central corneal thickness (CCT) can affect the accuracy of IOP measurement.
Chen M +6 more
europepmc +2 more sources