Comparison of rebound tonometry and non-contact airpuff tonometry to Goldmann applanation tonometry [PDF]

open access: yesTherapeutic Advances in Ophthalmology, 2019
Purpose: The aim of this study was to compare the intraocular pressure measurements obtained from healthy subjects with the rebound tonometry, non-contact airpuff tonometry, and Goldmann applanation tonometry in different age groups.
Sevil Karaman Erdur   +2 more
exaly   +8 more sources

Accuracy of dynamic contour tonometry, Goldmann applanation tonometry, and Tono-Pen XL in edematous corneas [PDF]

open access: yesTherapeutic Advances in Ophthalmology, 2020
Purpose: To investigate in vitro the accuracy of dynamic contour tonometry, Goldmann applanation tonometry, and Tono-Pen XL in edematous corneas. Methods: Experimental study included 20 freshly enucleated porcine eyes.
George A. Kontadakis   +5 more
doaj   +3 more sources

Comparison between dynamic contour tonometry and Goldmann applanation tonometry correcting equations [PDF]

open access: yesScientific Reports, 2022
In order to investigate the reliability of correcting GAT formulas in comparison with dynamic contour tonometry (DCT), this study included 112 right eyes of 112 healthy subjects aged from 21 to 77 years, whose eyes underwent to a full ophthalmologic exam.
Maddalena De Bernardo   +5 more
doaj   +2 more sources

Goldmann Tonometry and Corneal Biomechanics [PDF]

open access: yesApplied Sciences, 2021
Glaucoma is the second cause of irreversible blindness in the world. Intraocular pressure (IOP) is a recognized major risk factor for the development and progression of glaucomatous damage. Goldmann applanation tonometry (GAT) is internationally accepted
Dario Messenio   +2 more
doaj   +3 more sources

Comparison of ICare and IOPen vs Goldmann applanation tonometry according to international standards 8612 in glaucoma patients [PDF]

open access: yesInternational Journal of Ophthalmology, 2016
AIM: To compare IOPen and ICare rebound tonometry to Goldmann applanation tonometry (GAT) according to International Standards Organization (ISO) 8612 criteria. METHODS: Totally 191 eyes (n=107 individuals) were included.
Milena Pahlitzsch   +6 more
doaj   +2 more sources

CORRELATION BETWEEN INTRAOCULAR PRESSURE MEASUREMENTS USING APPLANATION TONOMETRY AND OCULAR RESPONSE ANALYZER (ORA) IN PRIMARY CONGENITAL GLAUCOMA (PCG) PATIENTS [PDF]

open access: yesEgyptian Journal of Clinical Ophthalmology, 2022
Objective: This study aims to assess the degree of agreement between IOP measured usingPerkins and Goldmann applanation tonometers, and both Goldmann correlated intraocular pressure(IOPg) and corneal compensated intraocular pressure (IOPcc) measured ...
Shokier, G., Khalil, N., Esmael, A.
doaj   +1 more source

Intraocular Pressure Measurement after Penetrating Keratoplasty

open access: yesDiagnostics, 2022
Assessing the intraocular pressure is a difficult but crucial task in the follow-up of patients that have undergone penetrating keratoplasty. Early recognition of elevated intraocular pressure and/or glaucoma and establishment of the appropriate ...
Otilia-Maria Dumitrescu   +3 more
doaj   +1 more source

Comparison among TonoVet, TonoVet Plus, Tono-Pen Avia Vet, and Kowa HA-2 portable tonometers for measuring intraocular pressure in dogs [PDF]

open access: yesVeterinary World, 2021
Background and Aim: Tonometers are an important instrument for measuring intraocular pressure (IOP) in the diagnosis of glaucoma or uveitis. This study aimed to compare the accuracy of the main types of tonometers with different IOP measurement ...
João Victor Goulart Consoni Passareli   +6 more
doaj   +1 more source

Reutilization of disposable rebound tonometer probes: Risk or return?

open access: yesIndian Journal of Ophthalmology, 2023
Purpose: An advantage of rebound tonometry (RT) is its ease of use so that it can also be operated by health care technicians. However, the cost of the disposable measuring probes is high and their reuse carries the risk of infection.
Christian Enders   +4 more
doaj   +1 more source

Intraocular pressure and ocular pulse amplitude using dynamic contour tonometry and contact lens tonometry

open access: yesBMC Ophthalmology, 2004
Background The new Ocular Dynamic Contour Tonometer (DCT), investigational device supplied by SMT (Swiss Microtechnology AG, Switzerland) allows simultaneous recording of intraocular pressure (IOP) and ocular pulse amplitude (OPA). It was the aim of this
Grus Franz-H   +2 more
doaj   +1 more source