Results 1 to 10 of about 6,770 (169)

Comparison of rebound tonometry and non-contact airpuff tonometry to Goldmann applanation tonometry [PDF]

open access: yesTherapeutic Advances in Ophthalmology, 2019
Purpose: The aim of this study was to compare the intraocular pressure measurements obtained from healthy subjects with the rebound tonometry, non-contact airpuff tonometry, and Goldmann applanation tonometry in different age groups.
Sevil Karaman Erdur   +2 more
exaly   +6 more sources

Comparison of Non-contact Tonometry and Goldmann Applanation Tonometry Measurements in Non-pathologic High Myopia [PDF]

open access: yesFrontiers in Medicine, 2022
PurposeTo compare intraocular pressure (IOP) values obtained using Goldmann applanation tonometry (IOPGAT) and non-contact tonometry (IOPNCT) in a non-pathologic high myopia population.MethodsA total of 720 eyes from 720 Chinese adults with non ...
Fengbin Lin   +2 more
exaly   +4 more sources

Comparison of ICare and IOPen vs Goldmann applanation tonometry according to international standards 8612 in glaucoma patients [PDF]

open access: yesInternational Journal of Ophthalmology, 2016
AIM: To compare IOPen and ICare rebound tonometry to Goldmann applanation tonometry (GAT) according to International Standards Organization (ISO) 8612 criteria. METHODS: Totally 191 eyes (n=107 individuals) were included.
Anna-Karina B Maier   +2 more
exaly   +3 more sources

Comparison between dynamic contour tonometry and Goldmann applanation tonometry correcting equations [PDF]

open access: yesScientific Reports, 2022
In order to investigate the reliability of correcting GAT formulas in comparison with dynamic contour tonometry (DCT), this study included 112 right eyes of 112 healthy subjects aged from 21 to 77 years, whose eyes underwent to a full ophthalmologic exam.
Maddalena De Bernardo   +5 more
doaj   +2 more sources

Accuracy of dynamic contour tonometry, Goldmann applanation tonometry, and Tono-Pen XL in edematous corneas [PDF]

open access: yesTherapeutic Advances in Ophthalmology, 2020
Purpose: To investigate in vitro the accuracy of dynamic contour tonometry, Goldmann applanation tonometry, and Tono-Pen XL in edematous corneas. Methods: Experimental study included 20 freshly enucleated porcine eyes.
George A. Kontadakis   +5 more
doaj   +2 more sources

Evaluation of agreement of IOP measurements by Tono-Vera tonometer to Goldmann applanation tonometry [PDF]

open access: yesFrontiers in Ophthalmology
PurposeTo evaluate the accuracy of the new Tono-Vera rebound tonometer (Reichert Inc, Buffalo, NY) compared to Goldmann Applanation Tonometry.MethodsThis prospective, observational, cross-sectional study was designed in accordance with ANSI Z80.10-2014 ...
Charles R. Niles   +3 more
doaj   +2 more sources

Clinical evaluation of corneal elasticity and true IOP using a dual-applanation tonometer [PDF]

open access: yesFrontiers in Ophthalmology
PurposeTo evaluate the clinical feasibility of a modified Goldmann applanation system capable of estimating true intraocular pressure and corneal elasticity in vivo.MethodsA dual-applanation prism was developed, allowing two sequential IOP readings under
C. Caruso   +5 more
doaj   +2 more sources

Goldmann applanation tonometry error relative to true intracameral intraocular pressure in vitro and in vivo [PDF]

open access: yesBMC Ophthalmology, 2017
Background Goldmann applanation tonometry (GAT) error relative to intracameral intraocular pressure (IOP) has not been examined comparatively in both human cadaver eyes and in live human eyes.
Sean McCafferty   +3 more
doaj   +2 more sources

Using Deep Learning to Automate Goldmann Applanation Tonometry Readings [PDF]

open access: yesOphthalmology, 2020
Ryan T Yanagihara   +2 more
exaly   +2 more sources

CORRELATION BETWEEN INTRAOCULAR PRESSURE MEASUREMENTS USING APPLANATION TONOMETRY AND OCULAR RESPONSE ANALYZER (ORA) IN PRIMARY CONGENITAL GLAUCOMA (PCG) PATIENTS [PDF]

open access: yesEgyptian Journal of Clinical Ophthalmology, 2022
Objective: This study aims to assess the degree of agreement between IOP measured usingPerkins and Goldmann applanation tonometers, and both Goldmann correlated intraocular pressure(IOPg) and corneal compensated intraocular pressure (IOPcc) measured ...
Shokier, G., Khalil, N., Esmael, A.
doaj   +1 more source