Comparison of rebound tonometry and non-contact airpuff tonometry to Goldmann applanation tonometry [PDF]
Purpose: The aim of this study was to compare the intraocular pressure measurements obtained from healthy subjects with the rebound tonometry, non-contact airpuff tonometry, and Goldmann applanation tonometry in different age groups.
Doç Goktug Demirci +2 more
exaly +6 more sources
Comparison between dynamic contour tonometry and Goldmann applanation tonometry correcting equations [PDF]
In order to investigate the reliability of correcting GAT formulas in comparison with dynamic contour tonometry (DCT), this study included 112 right eyes of 112 healthy subjects aged from 21 to 77 years, whose eyes underwent to a full ophthalmologic exam.
Maddalena De Bernardo +5 more
doaj +5 more sources
Dynamic contour tonometry versus Goldmann applanation tonometry: challenging the gold standard [PDF]
The accurate measurement of intraocular pressure (IOP) is fundamental to almost any ophthalmic examination. Dynamic contour tonometry (DCT) was introduced 5 years ago as an entirely novel contact tonometry principle designed to measure IOP largely ...
Claude Kaufmann
exaly +3 more sources
Accuracy of dynamic contour tonometry, Goldmann applanation tonometry, and Tono-Pen XL in edematous corneas [PDF]
Purpose: To investigate in vitro the accuracy of dynamic contour tonometry, Goldmann applanation tonometry, and Tono-Pen XL in edematous corneas. Methods: Experimental study included 20 freshly enucleated porcine eyes.
George A. Kontadakis +5 more
doaj +4 more sources
Using Deep Learning to Automate Goldmann Applanation Tonometry Readings [PDF]
To develop an objective and automated method for measuring intraocular pressure using deep learning and fixed-force Goldmann applanation tonometry (GAT) techniques.Prospective cross-sectional study.Patients from an academic glaucoma practice.Intraocular pressure was estimated by analyzing videos recorded using a standard slit-lamp microscope and fixed ...
Theodore Spaide +2 more
exaly +5 more sources
Evaluation of agreement of IOP measurements by Tono-Vera tonometer to Goldmann applanation tonometry [PDF]
PurposeTo evaluate the accuracy of the new Tono-Vera rebound tonometer (Reichert Inc, Buffalo, NY) compared to Goldmann Applanation Tonometry.MethodsThis prospective, observational, cross-sectional study was designed in accordance with ANSI Z80.10-2014 ...
Charles R. Niles +3 more
doaj +4 more sources
Comparison of Goldmann applanation tonometry and Pascal dynamic contour tonometry in relation to central corneal thickness and corneal curvature [PDF]
Konstantinos Andreanos, Chryssanthi Koutsandrea, Dimitris Papaconstantinou, Andreas Diagourtas, Andreas Kotoulas, Panagiotis Dimitrakas, Marilita M Moschos First Department of Ophthalmology, University of Athens, “G.
Andreanos K +6 more
doaj +4 more sources
Anne Herr,1 Andreas Remky,2 Thalia Hirsch,1 Corinna Rennings,1 Niklas Plange1 1Department of Ophthalmology, RWTH Aachen University, Aachen, Germany; 2Augenbelegabteilung Krankenhaus Barmherzige Brueder, Regensburg, Germany Introduction: Intraocular ...
Herr A +4 more
doaj +6 more sources
Evaluation of Goldmann applanation tonometry, rebound tonometry and dynamic contour tonometry in keratoconus [PDF]
Maddalena De Bernardo, Nicola Rosa
doaj +4 more sources
Comparison of Non-contact Tonometry and Goldmann Applanation Tonometry Measurements in Non-pathologic High Myopia [PDF]
PurposeTo compare intraocular pressure (IOP) values obtained using Goldmann applanation tonometry (IOPGAT) and non-contact tonometry (IOPNCT) in a non-pathologic high myopia population.MethodsA total of 720 eyes from 720 Chinese adults with non ...
Peiyuan Wang +10 more
doaj +2 more sources