Evaluation of Goldmann applanation tonometry, rebound tonometry and dynamic contour tonometry in keratoconus [PDF]
Maddalena De Bernardo, Nicola Rosa
doaj +4 more sources
Purpose: To compare the intraocular pressure (IOP) measurements obtained with the rebound tonometry (RT), dynamic contour tonometry (DCT) and Goldmann applanation tonometry (GAT) in keratoconic corneas and to investigate the effects of central corneal ...
Fatih Özcura +3 more
doaj +3 more sources
Background. To evaluate differences between Goldmann Applanation Tonometry (GAT) and Dynamic Controur Tonometry (DCT) following trabeculectomy. Methods. Thirty eight glaucomatous eyes with a history of trabeculectomy (Trabeculectomy group, TG), 20 eyes ...
Efstathios T. Detorakis +3 more
doaj +3 more sources
Intraocular Pressure Measurement after Penetrating Keratoplasty
Assessing the intraocular pressure is a difficult but crucial task in the follow-up of patients that have undergone penetrating keratoplasty. Early recognition of elevated intraocular pressure and/or glaucoma and establishment of the appropriate ...
Otilia-Maria Dumitrescu +3 more
doaj +1 more source
Comparison of Goldmann applanation tonometry and Icare tonometry
AbstractPurposeTo compare the variation of intraocular pressure (IOP) measured with Goldmann applanation tonometry (GAT) and Icare tonometry, and further determine if the two methods were calibrated to each other.MethodsTotally 20 subjects within normal IOP range were evenly divided into two method groups.
Zhaohua Yu +3 more
openaire +1 more source
Comparison among TonoVet, TonoVet Plus, Tono-Pen Avia Vet, and Kowa HA-2 portable tonometers for measuring intraocular pressure in dogs [PDF]
Background and Aim: Tonometers are an important instrument for measuring intraocular pressure (IOP) in the diagnosis of glaucoma or uveitis. This study aimed to compare the accuracy of the main types of tonometers with different IOP measurement ...
João Victor Goulart Consoni Passareli +6 more
doaj +1 more source
Comparison Between Dynamic Contour Tonometry and Goldmann Applanation Tonometry [PDF]
To compare the intraocular pressures (IOPs) measured by dynamic contour tonometry (DCT) and Goldmann applanation tonometry (GAT), and to investigate the association of IOPs on eyes of varying central corneal thickness (CCT).In this prospective study, 451 eyes of 233 subjects were enrolled. IOPs were measured by GAT and DCT. CCT was measured three times
Lee, Jooeun +6 more
openaire +2 more sources
Systematic Review of the Agreement of Tonometers with Goldmann Applanation Tonometry [PDF]
To assess the agreement of tonometers available for clinical practice with the Goldmann applanation tonometer (GAT), the most commonly accepted reference device.A systematic review and meta-analysis of directly comparative studies assessing the agreement of 1 or more tonometers with the reference tonometer (GAT).A total of 11 582 participants (15 525 ...
Cook, Jonathan Alistair +8 more
openaire +5 more sources
Goldmann Tonometry and Corneal Biomechanics
Glaucoma is the second cause of irreversible blindness in the world. Intraocular pressure (IOP) is a recognized major risk factor for the development and progression of glaucomatous damage. Goldmann applanation tonometry (GAT) is internationally accepted
Dario Messenio +2 more
doaj +1 more source
Comparison of Dynamic Contour Tonometry with Goldmann Applanation Tonometry
The dynamic contour tonometer (DCT; Pascal tonometer) is a novel tonometer designed to measure intraocular pressure (IOP) independent of corneal properties. The purpose of this study was a comparison of the DCT with the Goldmann applanation tonometer (GAT) with respect to mean of IOP readings, the influence of ocular structural factors on IOP readings,
Kaufmann C, Bachmann LM, Thiel MA
openaire +3 more sources