Results 211 to 220 of about 1,722,670 (273)

Material Selection and Geometric Design for Few‐filament Shape Memory Polymer Yarns for Force Generation

open access: yesAdvanced Materials Technologies, EarlyView.
A custom shape memory polymer material selection process relates quantitative application criteria (e.g., compression garment yarns) to material characterization information. The selected materials are manufactured into yarn geometries, which expand the design space by creating structural stress‐strain profiles beyond the nominal material stress‐strain
Michaela Andrews   +2 more
wiley   +1 more source

In Situ Copper Electroplating Turns Material Extrusion 3D Printers Into Metal–Polymer Hybrid Fabricators

open access: yesAdvanced Materials Technologies, EarlyView.
An in situ electroplating approach for MEX 3D printing is proposed, enabling copper deposition during the fabrication of conductive polymers. The method combines a printer‐integrated plating head, ML‐based g‐code control, and stop‐and‐go printing, achieving near‐bulk copper conductivity and enabling fully embedded, assembly‐free electronic components ...
Gianluca Percoco   +5 more
wiley   +1 more source

A Pressure Microsensor Made of Parylene‐C for Use as Medical Implant

open access: yesAdvanced Materials Technologies, EarlyView.
A monolithic parylene‐C pressure sensor with gold strain gauges provides 6.2 μV$\mu{\rm V}$·mmHg$\cdot{\rm mmHg}$−1$^{-1}$ sensitivity. The morphology of a sputtered thin film strain sensor is granular/columnar, which results in a high gauge factor of 7.5. Thermal bonding and parylene‐C coating create a hermetic cavity.
Ann‐Kathrin Klein   +2 more
wiley   +1 more source

Cap‐oPMN: Oral Inflammatory Load Quantification Using Capillary Microfluidics and Automated Image Processing

open access: yesAdvanced Materials Technologies, EarlyView.
ABSTRACT Quantifying oral polymorphonuclear neutrophils (oPMNs) is a clinically validated approach for assessing periodontal inflammation. However, current methods, such as manual hemocytometry and flow cytometry, are time‐consuming (>3 h), require invasive sampling, and depend on staining and complex instrumentation, making them unsuitable for point ...
Mohsen Hassani   +9 more
wiley   +1 more source

Galinstan Liquid Metal/Polyurethane Composite as a Multifunctional Stretchable Electrode and Piezoresistive Strain Sensor With Minimal Drift

open access: yesAdvanced Materials Technologies, EarlyView.
Liquid metal additives are processed in elastomer host resulting in highly conductive and stretchable composites. The material functions as a piezoresistive sensor with minimal drift, low stiffness, and enhanced operating range. The film can replace wires to charge a mobile phone at ∼350% strain and monitors bodily motion in real‐time via a portable ...
Patryk Wojciak   +3 more
wiley   +1 more source

Home - About - Disclaimer - Privacy