Results 81 to 90 of about 22,042 (209)
Detecting pantograph-catenary arcing on trains is crucial for ensuring safety in railway operation and maintenance. Most existing detection methods rely on optical instruments to capture pantograph-catenary images, followed by the analysis of these ...
LUO Yinbei, GE Ting, SUN Zeyong
doaj
The Space Station Photovoltaic Panels Plasma Interaction Test Program: Test plan and results [PDF]
The Plasma Interaction Test performed on two space station solar array panels is addressed. This includes a discussion of the test requirements, test plan, experimental set-up, and test results.
Felder, Marian C. +3 more
core +1 more source
Development of diagnostic and prognostic algorithms for SF6 puffer circuit breakers from transient waveforms: a validation proposal [PDF]
- This paper presents a validation proposal for development of diagnostic and prognostic algorithms for SF6 puffer circuit-breakers reproduced from actual site waveforms.
Kam, Shui-cheong, Ledwich, Gerard
core +1 more source
The explosion accident due to the internal arc fault in the metal‐enclosed switchgear cannot be ignored. Therefore, improving the ability of switchgear to resist the arc fault has important significance.
Peng Li +5 more
doaj +1 more source
As the operating speed of electric multiple units (EMUs) in high-speed railways increases, pantograph–catenary (PC) detachment arcing occurs frequently.
Ke Huang, Dongdong Su
doaj +1 more source
Motion studies of high current arcs using an optical fibre array imaging system
This paper presents an integrated portable measurement system for thestudy of high speed and high temperature unsteady plasma flows such as thosefound in the vicinity of high current switching arcs.
Cross, K. +3 more
core
The high voltage direct current (HVDC) transmission lines represent the prospective way for long-distance transmission between countries, remote areas, and offshore wind farms to decrease power loss.
Tamer Eliyan +4 more
doaj +1 more source
Research on Online Monitoring Methods on SF6 Circuit Breakers
To promote the accuracy and application of arcing time measurement for SF6 circuit breaker in substation,five measurement methods are investigated by two cases experimentally.
CHENG Tingting +2 more
doaj
Establishing a compartment fire's area of origin when it has been burning at post-flashover conditions is a difficult process. Burn patterns traditionally used by fire investigators following post-flashover fires can be erroneous.
Carey, Nicholas, NicDaeid, N.
core +1 more source
Environmental interactions and the SP-100 power system [PDF]
Interactions of the SP-100 power system with its expected ambient environments are defined. SP-100 payloads will float 100 V negative of the low Earth orbit (LEO) plasma.
Ferguson, Dale C.
core +1 more source