Results 1 to 10 of about 3,286,995 (272)
A New Control Logic for a Wind-Area on the Balancing Authority Area Control Error Limit Standard for Load Frequency Control [PDF]
Nowadays, the Balancing Authority Area Control Error (ACE) Limit (BAAL) Standard has been adopted to replace the Control Performance Standard 2 (CPS2) in the North American power grid. According to the new standard’s mechanism, a new control logic, named
Yekui Chang, Rao Liu, Yu Ba, Weidong Li
doaj +2 more sources
Two-Layer Error Control Codes Combining Rectangular and Hamming Product Codes for Cache Error [PDF]
We propose a novel two-layer error control code, combining error detection capability of rectangular codes and error correction capability of Hamming product codes in an efficient way, in order to increase cache error resilience for many core systems ...
Meilin Zhang, Paul Ampadu
doaj +4 more sources
Enhancement of PID controller performance for a combined LFC and AVR single- and two-area model using exponential distribution optimization technique [PDF]
This study presents the exponential distribution optimization (EDO) technique for tuning the proportional-integral-derivative (PID) controller parameters in combined load frequency control (LFC) and automatic voltage regulation (AVR) for both single- and
Mohamed S. Amin +3 more
doaj +2 more sources
This study presents automatic generation control (AGC) of interconnected power systems comprising of two thermal and one hydro area having integral controllers. Emphasis is given to a delay in the area control error for the actuation of the supplementary
Janardan Nanda +2 more
doaj +2 more sources
Optimization of Automatic Generation Control and Economic Load Dispatch for Two Area Six Unit Interconnected Power System [PDF]
This paper proposes an integrated Economic Load Dispatch (ELD) and Automatic Generation Control (AGC) for interconnected power systems. Based on their participation factor determined from the economic load dispatch calculation, each unit shares the total
Faeq Zwayyer +2 more
doaj +1 more source
Electrochemical energy storage responds to tie-line power deviation in seconds, while the indexes CPS1 and CPS2 that measure the tie-line power deviation are computed by the cumulative value of tie-line power deviation in minutes, thus making it hard to ...
Shaoqun SONG +6 more
doaj +1 more source
As more and more unconventional energy sources are being applied in the field of power generation, the frequency fluctuation of power system becomes more and more serious.
Gaojun Meng +6 more
doaj +1 more source
Electricity demand continues to rise on a daily basis. The most difficult task is ensuring that customers have access to reliable, high-quality electricity regardless of the weather.
Muntasir A. Magzoub, Thamer Alquthami
doaj +1 more source
Area control error enhancement of two-area power system using hybrid intelligence optimal controller
Area control error (ACE) is a critical factor in linked power systems. When a disturbance occurs, ACE is utilized to determine how much power should be deployed. As a result, it is critical that the ACE have as little inaccuracy as feasible. This research provided a strategy for improving the dynamic response of ACE in a power system.
Muhammad Abdillah, Herlambang Setiadi
openaire +1 more source
A power system’s nonlinearity and complexity increase from time to time due to increases of power demand. Therefore, properly designed power system controlsare required.
Solomon Feleke +4 more
doaj +1 more source

