Results 1 to 10 of about 1,482,813 (348)

Fault Current Characteristics of the DFIG under Asymmetrical Fault Conditions [PDF]

open access: yesEnergies, 2015
During non-severe fault conditions, crowbar protection is not activated and the rotor windings of a doubly-fed induction generator (DFIG) are excited by the AC/DC/AC converter.
Fan Xiao, Zhe Zhang, Xianggen Yin
doaj   +3 more sources

Improved DFIG capability during asymmetrical grid faults [PDF]

open access: yesIECON 2015 - 41st Annual Conference of the IEEE Industrial Electronics Society, 2015
In the wind power application, different asymmetrical types of the grid fault can be categorized after the Y/d transformer, and the positive and negative components of a single-phase fault, phase-to-phase fault, and two-phase fault can be summarized.
Dao Zhou, Frede Blaabjerg
core   +7 more sources

Asymmetrical Fault Current Calculation Method and Influencing Factors Analysis of Droop-Controlled Inverters

open access: yesCSEE Journal of Power and Energy Systems, 2021
Since the fault dynamic of droop-controlled inverter is different from synchronous generators (SGs), protection devices may become invalid, and the fault overcurrent may damage power electronic devices and threaten the safety of the microgrid. Therefore,
Huimin Zhao   +5 more
doaj   +2 more sources

Asymmetrical Fault Correction for the Sensitive Loads Using a Current Regulated Voltage Source Inverter

open access: yesEnergies, 2016
Numerous industrial applications involve loads that are very sensitive to electrical supply instabilities. These instances involve various types of voltage imbalances as well as more serious disturbances such as symmetrical and asymmetrical faults.
Syed Sabir Hussain Bukhari   +3 more
doaj   +2 more sources

An Adaptive Fault Ride-Through Scheme for Grid-Forming Inverters Under Asymmetrical Grid Faults

open access: yesIEEE Transactions on Industrial Electronics, 2022
202206 bchy ; Accepted Manuscript ; RGC ; Others ; Innovation and Technology Commission of the HKSAR Goverment ; Published ; Green (AAM)
Zilin Li   +3 more
openaire   +3 more sources

A Novel Technique for Asymmetrical Fault A Novel Technique for Asymmetrical Fault Detection

open access: yesBulletin of Electrical Engineering and Informatics, 2012
Qingchao Yang   +3 more
semanticscholar   +4 more sources

Fault Tolerant CCS-MPC for Asymmetrical DTP-PMSM Drives Assisted by Fault Detection Algorithm

open access: yesIEEE Access
Fault tolerance is a highly desirable feature for safety-critical electric drive applications. This paper proposes an open-circuit fault tolerant model predictive controller (FT-MPC) for asymmetrical dual three-phase (DTP) permanent magnet synchronous ...
Adriano Navarro-Temoche   +4 more
doaj   +3 more sources

Active fault tolerant control for twin wind turbine subject to asymmetric fault [PDF]

open access: yes2021 International Conference on Control, Automation and Diagnosis (ICCAD), 2021
This paper addresses the problem of control of a twin wind turbine which is subject to an electrical fault affecting only one stator phase of one turbine. An active fault tolerant control is proposed. The performance and robustness of the proposed control, comparing to a passive fault tolerant one developed in the literature, are shown through ...
Makni, Mariem   +5 more
openaire   +3 more sources

Asymmetrical Fault Ride-Through and Power Oscillation Characterization for Grid-Tied Voltage Source Converters

open access: yesIEEE transactions on industry applications, 2023
As the number of converter-interfaced distributed energy resources connected to the power system continues to increase rapidly, recent grid codes require these grid-tied converters to maintain grid connection during faults to ensure power supply security
Md Rifat Kaisar Rachi   +2 more
semanticscholar   +1 more source

Simulation-based post-fault analysis in WECS using DFIG systems under an unbalanced fault scenario

open access: yesJournal of Applied Research in Technology & Engineering, 2023
Fault analysis in an integrated Wind Energy Conversion System (WECS) is the highest priority factor to be taken into account for distributed generation (DG).
Muzamil Hussain Wadho   +3 more
doaj   +1 more source