Results 1 to 10 of about 1,053 (261)
Improved DFIG capability during asymmetrical grid faults [PDF]
In the wind power application, different asymmetrical types of the grid fault can be categorized after the Y/d transformer, and the positive and negative components of a single-phase fault, phase-to-phase fault, and two-phase fault can be summarized.
Dao Zhou, Frede Blaabjerg
openaire +3 more sources
The Injana field area is located to the north of Baquba city within Diyala. which was studied and interpreted by using 2D seismic data from the Oil Exploration Company.
Mustafa Ahmed +2 more
doaj +1 more source
Grid faults are found to be one of the major issues in renewable energy systems, particularly in wind energy conversion systems (WECS) connected to the grid via back-to-back (BTB) converters.
Syed Wajahat Ali +6 more
doaj +1 more source
Modular multilevel converter (MMC)-based high voltage direct current (HVDC) transmission networks integrate remotely located distributed renewable energy resources (RER). The intermittent nature of RER and symmetrical and asymmetrical AC-side low-voltage
Md Ismail Hossain +4 more
doaj +1 more source
Analytical Model of Induction Machines with Multiple Cage Faults Using the Winding Tensor Approach
Induction machines (IMs) are one of the main sources of mechanical power in many industrial processes, especially squirrel cage IMs (SCIMs), due to their robustness and reliability.
Javier Martinez-Roman +5 more
doaj +1 more source
Identification and location method of asymmetric faults in coal mine power network
Three asymmetrical faults of singe-phase grounding, singe-phase line breakage and ferroresonance in coal mine power network are easily misjudged, and existing methods hardly identify the three faults correctly.
WANG Qingliang, QIN Jie, LIU Xinru
doaj +1 more source
Synchronization method for grid integrated battery storage systems during asymmetrical grid faults [PDF]
This paper aims at presenting a robust and reliable synchronization method for battery storage systems during asymmetrical grid faults. For this purpose, a Matlab/Simulink based model for testing of the power electronic interface between the ...
Popadić Bane +4 more
doaj +1 more source
Structural Study of Judaida Subsurface Structure, North of Iraq
This research focuses on the structural study of three folded horizons of Fat'ha, Jeribe, and the Euphrates in Judaida structure, Northern Iraq. Depth contour maps for three horizons using the time and velocity data called from seismic surveys.
Omar A. Naji +2 more
doaj +1 more source
Synchronous Power Control of Grid-Connected Power Converters under Asymmetrical Grid Fault
Control of grid-connected power converters is continuously developing to meet the grid codes, according to which the generation units should keep connected to the grid and further provide ancillary services, such as voltage and frequency support ...
Weiyi Zhang +3 more
doaj +1 more source
Influence of Negative Sequence Injection Strategies on Faulted Phase Selector Performance
Renewable power is expected to increase drastically in the coming years due to the energy transition. A large part of the newly installed generators will be connected to the power system through inverters and electronic converters, whose behaviour ...
María Teresa Villén +3 more
doaj +1 more source