Results 21 to 30 of about 1,055 (260)
Influence of Negative Sequence Injection Strategies on Faulted Phase Selector Performance
Renewable power is expected to increase drastically in the coming years due to the energy transition. A large part of the newly installed generators will be connected to the power system through inverters and electronic converters, whose behaviour ...
María Teresa Villén +3 more
doaj +1 more source
The negative-sequence current component and harmonic components generated when an asymmetrical fault occurs in the power grid seriously affect the normal operation of the photovoltaic (PV) grid-connected inverter.
Shiji Tian +3 more
doaj +1 more source
Numerous industrial applications involve loads that are very sensitive to electrical supply instabilities. These instances involve various types of voltage imbalances as well as more serious disturbances such as symmetrical and asymmetrical faults.
Syed Sabir Hussain Bukhari +3 more
doaj +1 more source
This paper studies a real 36-MW large tubular hydro-generator to solve the transient variation problem of the loss and heat of damper bars during short circuit faults in tubular hydro-generators.
Qing-Ling Hu +7 more
doaj +1 more source
This work provides a theoretical/methodological contribution to the transient analysis of asymmetrical faults in three-phase systems. Transient analysis of three-phase systems is usually performed by resorting either to the instantaneous Symmetrical ...
Diego Bellan
doaj +1 more source
Sliding Mode Control Based Supercapacitor Modeling for Dynamic Stability in DFIG Based Wind Turbines
The supercapacitor is among the elements commonly used to store energy as an important component in sustainable energy systems. In doubly fed induction generators (DFIGs), the supercapacitor is used to compensate voltage dips and damping oscillations. In
Uğur Güvenç +2 more
doaj +1 more source
We present robust protocols for the preparation of supported lipid bilayers (SLBs) incorporating either Salmonella smooth LPS or outer membrane vesicles (OMVs). We use a combination of quartz crystal microbalance with dissipation (QCM‐D) and fluorescence microscopy to both characterize the SLBs of various compositions and to probe their interactions ...
Hudson P. Pace +6 more
wiley +1 more source
Influence of fault asymmetric dislocation on the gravity changes
Abstract:A fault is a planar fracture or discontinuity in a volume of rock, across which there has been significant displacement along the fractures as a result of earth movement. Large faults within the Earth’s crust result from the action of plate tectonic forces, with the largest forming the boundaries between the plates, energy release associated ...
Duan Hurong, Wang Tao
openaire +2 more sources
Effect of Asymmetric Topography on Rupture Propagation Along Fault Stepovers
Abstract Complex fault systems are often located in regions with asymmetric topography on one side of a fault, and these systems are very common in Southern California. Along these fault systems, geometrical complexities such as stepovers can impact fault rupture.
openaire +1 more source
Determination of SCC Contributed by DFIG Under Asymmetrical Short Circuit Fault
For the past decades, practical calculation method of short circuit current (SCC) contributed by doubly fed induction generator (DFIG) under asymmetrical short circuit fault is deficient due to its control strategies and unlinear equipment.
Wenjia Xu +4 more
doaj +1 more source