Fault ride-through of renewable energy conversion systems during voltage recovery
Asymmetrical voltage swells during recovery of a short-circuit fault lead to fluctuations in the dc-link voltage of a renewable energy conversion system (RECS), and may induce reversed power flow and even trip the RECS. This paper studies characteristics
Ruiqi Li, Hua Geng, Geng Yang
doaj +1 more source
Fault-tolerance Design and Validation of Power Converter [PDF]
In order to improve the reliability of the Switch Reluctance Generation(SRG)system,several common failures of power converter are analyzed.Combined with the superiority of the independence of asymmetrical bridge power converter,a kind of fault-tolerant ...
ZHOU Zheng,LIU Yongzhi,SONG Jinlong,MA Weimin,WANG Zhenliang
doaj +1 more source
IPM synchronous machine drive response to symmetrical and asymmetrical short circuit faults [PDF]
Copyright © 2003 IEEEA closed-form solution is presented for the steady-state response of interior permanent magnet (IPM) synchronous machines to symmetrical short circuits including the effects of q-axis magnetic saturation.
Jahns, T. +3 more
core +1 more source
Identification and location method of asymmetric faults in coal mine power network
Three asymmetrical faults of singe-phase grounding, singe-phase line breakage and ferroresonance in coal mine power network are easily misjudged, and existing methods hardly identify the three faults correctly.
WANG Qingliang, QIN Jie, LIU Xinru
doaj +1 more source
Assessment of a Universal Reconfiguration-less Control Approach in Open-Phase Fault Operation for Multiphase Drives [PDF]
Multiphase drives have been important in particular industry applications where reliability is a desired goal. The main reason for this is their inherent fault tolerance. Di erent nonlinear controllers that do not include modulation stages, like direct
Barrero, Federico +4 more
core +2 more sources
Influence Mechanism and Suppression Control of the MMC on Short-Circuit Current Under AC Faults
Modular multilevel converter based high voltage direct current (MMC-HVDC) transmission systems may increase the short-circuit current and affect the AC fault clearing of circuit breakers.
Jian Yang +3 more
doaj +1 more source
Fault and magmatic interaction within Iceland's western rift over the last 9kyr [PDF]
We present high-resolution 'Chirp' sub-bottom profiler data from Thingvallavatn, a lake in Iceland's western rift zone. These data are combined with stratigraphic constraints from sediment cores to show that movement on normal faults since 9 ka are ...
A. I. Best +13 more
core +1 more source
Research on magnetic field and temperature field of multi-phase SPMSM under winding fault
In order to quickly and accurately calculate fault-tolerant capability of multi-phase surface-mount permanent magnet synchronous motor (SPMSM) at condition of asymmetrical fault, based on subdomain model, an analytical model for multi-phase SPMSM with ...
Zhanyang Yu +4 more
doaj +1 more source
The asymmetric faults often cause the power grid current imbalance and power grid oscillation, which brings great instability risk to the power grid.
Li Wang +4 more
doaj +1 more source
Fault suppression strategy of active compensators in asymmetric distribution networks
The new-type distribution network with a high penetration of distributed generation (DG) faces challenges such as significant power fluctuations and the inability to fully compensate for single-phase grounding fault currents.
Jian-zhang You +3 more
doaj +1 more source

