Results 31 to 40 of about 1,165 (176)
During the last decade, many industrial and medical applications have shown a requirement for low-temperature-cooling usage (from −40 to −80 °C), which cannot be efficiently obtained via the conventional refrigeration systems usually employed for medium ...
Muhammad Zahid Saeed +5 more
doaj +1 more source
In order to study the performance of the new environment-friendly refrigerant mixture, chemical simulation software was used in this study to simulate the compressor exhaust temperature, compression work, evaporator evaporation temperature, system ...
LIU Yang +3 more
doaj +1 more source
Experimental investigation of the performance of a single-stage auto-cascade refrigerator [PDF]
Auto-refrigerating cascade (ARC) systems possess many advantages comparing with traditional cascade refrigeration systems. This work proposed a novel ternary mixture, R600a/R23/R14, for ARC systems for 190 K applications. The performance of the ternary mixture and the influences of compositional ratio and bypass scheme were assessed in a modified ...
Rui, S, Zhang, H, Zhang, B, Wen, D
openaire +2 more sources
Experimental Study of the effects of Throttle valve on Auto-cascade Refrigeration System [PDF]
The objection of this article is to optimize auto-cascade refrigeration system. This refrigeration system use multiple mixture (R22/R23/R14) as the refrigerant, which is driven by the single-stage compressor. Throttle is an important composition of auto-cascade refrigerant system, which impact on evaporation temperature and refrigeration efficiency ...
Li Xiang +6 more
openaire +1 more source
CO2 as a natural and fully environmentally friendly refrigerant has become more preferable in refrigeration systems in recent years. Since its critical temperature is much lower than that of other refrigerants.
YILMAZ, BARIŞ
core +2 more sources
The Relation of Performance Parameters for a 150K Auto-Cascade Refrigeration System
The performance parameters of a single compressed and four-stage segregating auto-cascade refrigeration system were developed in this study. The temperature of the cryogenic tank went down relatively slow with the evaporating temperature and the refrigerant temperature for W. When the state of system is steady, the suction pressure of the compressor is
XueLi Nie +3 more
openaire +1 more source
Performance Experiment of R290/CO2 Cascade Refrigeration System [PDF]
Performance experiments of R290/CO2 cascade refrigeration system were conducted. The performance of a cascade refrigeration system having a high temperature cycle using R290 as refrigerant and a CO2 based low temperature cycle was compared with that of a
宁静红, 彭苗, 李惠宇
core +1 more source
ABSTRACT A recombinant whole‐cell biocatalytic approach provides several advantages over isolated enzymes, such as improved enzyme stability, in vivo cofactor regeneration, and the facilitation of cascade reactions within a single cell. Whole‐cell biocatalysis has gained attention in medicinal opioid production, due to its technical and economic ...
Ali Jahanian +4 more
wiley +1 more source
ABSTRACT Circular product design (CPD) is central to advancing the circular economy by enabling the narrowing, slowing, and closing of resource flows. Yet, its implementation remains persistently challenging for firms. Prior research has largely framed these challenges as discrete barriers, overlooking the structural contradictions embedded in CPD ...
Vanessa Robertson +2 more
wiley +1 more source
Artificial cell: An emerging bioactive material with advanced applications in cancer theranostics
Artificial cells are emerging as attractive biomimetic bioactive materials that recapitulate key structures and functions of natural cells. This review systematically summarizes their major types, versatile fabrication strategies, tuneable properties and programmable biomimetic behaviours, highlights their cutting‐edge integrated applications in cancer
Daikun Wu, Shuo Yang, Hongjing Dou
wiley +1 more source