Results 21 to 30 of about 1,165 (176)

Experimental optimization and evaluation of an R600a/R1150 auto-cascade refrigeration systems for ultra-low temperature applications

open access: yesResults in Engineering
Auto-cascade refrigeration systems are the most employed systems for ultra-low temperature applications, especially for small capacity systems. Recent investigations have allowed to analyze them energetically and thermodynamically, starting a research ...
Manel Martínez-Ángeles   +3 more
doaj   +2 more sources

Experimental Study on Throttle Opening in Auto-cascade Refrigeration System

open access: yesZhileng xuebao, 2005
An advanced experimental apparatus with a rectification column was set up.In the experiments,environmental protection refrigerant mixtures were employed as working fluid and the influences of throttle opening on refrigeration temperature,rectification ...
王生龙, 陈光明, 王勤
doaj   +2 more sources

Performance analysis of a modified ejector-enhanced auto-cascade refrigeration cycle

open access: yesEnergy, 2022
Abstract This study presents the experimental investigation of an ejector-enhanced auto-cascade refrigeration cycle (EARC) with zeotropic refrigerant R134a/R23. Performance comparisons among the EARC and two conventional cycles were conducted at selected operating conditions.
Shuilong Liu   +3 more
  +8 more sources

The Exploratory Research on Mixed Refrigerants of A Five-Stage Autocascade Refrigeration System [PDF]

open access: yesZhileng xuebao, 2011
A five-stage Auto-cascade refrigeration cycle(ARC) is brought forward.According to the experiences that different systems with different components and proportion of mixed refrigerants can result in different evaporating temperature,the components ...
doaj   +5 more sources

A Framework for Emergency Department-Integrated Hepatitis C Test-and-Treat in the United States. [PDF]

open access: yesJ Viral Hepat
ABSTRACT Despite the availability of curative, direct‐acting antiviral therapy, hepatitis C virus elimination remains incomplete. Losses across the care cascade continue to limit impact, from initial diagnosis to sustained virologic response. Fewer than 1/3 of individuals ultimately achieve cure. These gaps reflect a delivery system that does not align
Graham SS.
europepmc   +2 more sources

Composition Change Characteristics of Non-azeotropic Mixturesof Auto- cascade Refrigeration System

open access: yesZhileng xuebao, 2016
The condensation process of non-azeotropic mixed refrigerant is a isobaric process. Meanwhile, the concentrations of vapor and liquid continuously change.
Rui Shengjun, Zhang Hua, He Tao, Luo Hao
doaj   +1 more source

Performance of a Small-sized Auto-cascade Refrigerator with a Fractionation Heat Exchanger

open access: yesZhileng xuebao, 2015
A fractionation heat exchanger was employed to improve the separation efficiency of CO2 and propane in the small-sized auto-cascade refrigeration cycle.
Zhang Li   +5 more
doaj   +1 more source

Mesenchymal Stem Cell-Derived Apoptotic Micro-Vesicles Repaired Sciatic Nerve Defect by Regulating Early Inflammatory Microenvironment and Promoting Angiogenesis. [PDF]

open access: yesAdv Healthc Mater
HUCMSC‐Apo‐mvs enhance peripheral nerve repair by modulating the inflammatory microenvironment (IME), primarily through coordinated actions on three functional cells. They recruit macrophages and promote their polarization from pro‐inflammatory M1 to anti‐inflammatory M2 phenotypes, increasing secretion of IL‐10 and VEGF.
Liu H   +21 more
europepmc   +2 more sources

Molecular dynamics simulation of non-azeotropic refrigerants separation in auto-cascading refrigeration [PDF]

open access: yesE3S Web of Conferences, 2019
The core problem of auto-cascading refrigeration is the separation of non-azeotropic refrigerants. The separation effect of mixed refrigerant directly determines the refrigeration effect of auto-cascading refrigeration system and the value of COP. The microscopic molecular dynamics simulation method is applied to the refrigeration system, and the ...
Zheng Dayu   +3 more
openaire   +2 more sources

Theoretical gas phase compressibility factor of mixed refrigerants in auto-cascade refrigeration system [PDF]

open access: yesProceedings of the 5th International Conference on Advanced Design and Manufacturing Engineering, 2015
KEYWORD: auto -cascade; mixed refrigerants; gas phase compressibility factor; ratio of refrigerant ABSTRACT: The compressibility factor is solved using the RKS equation and the corresponding calculation program. Redlich-kwongSoave the numerical calculation method for solving the compressibility factor, R22 and CO2 is calculated and compare it with ...
Jie Li   +7 more
openaire   +1 more source

Home - About - Disclaimer - Privacy