Results 1 to 10 of about 5,058 (187)
The cooling capacity needed by ultra-low temperature apparatus cannot be reached economically with a single vapor compression refrigeration cycle due to the constraint of the high compressor pressure ratio.
Zhenzhen Liu +3 more
doaj +5 more sources
Energy and exergy analysis of a modified three-stage auto-cascade refrigeration cycle using low-GWP refrigerants for sustainable development. [PDF]
This study proposed a modified three-stage auto-cascade refrigeration cycle (MTARC) operating with environmentally benign zeotropic mixture of R1234yf/R170/R14 at the refrigeration temperature level of - 80 °C. Compared with the conventional three-stage auto-cascade refrigeration cycle (CTARC), MTARC incorporates an additional pressure regulator ...
Qin Y, Li N, Zhang H, Liu B.
europepmc +3 more sources
Development Status of Auto-cascade Refrigeration Technology
As a refrigeration technology with wide-temperature district, auto-cascade refrigeration has a very broad application prospect in the refrigeration and cryogenic field.
Liu Pengpeng +3 more
doaj +1 more source
Study on Application of Double-pipe Condenser for Auto-cascade Refrigeration
Auto-cascade refrigeration system is widely used to obtain low temperature environment between -40 ℃ ~ -150 ℃. Double-pipe condenser is commonly regarded for condensing equipment in auto-cascade refrigeration system, its characteristics and structure ...
Rui Shengjun +3 more
doaj +3 more sources
Study on Mixed Refrigerants Selecting and Matching of a Four Stage Auto-cascade Refrigeration
The selection and mixture ratio of the mixed refrigerants are important to a multistage auto-cascade refrigeration system. A simulation method was found for the mixed refrigerants selection and ratio calculation by using the commercial software REFPROP8 ...
Zhao Wei +4 more
doaj +1 more source
Composition Change Characteristics of Non-azeotropic Mixturesof Auto- cascade Refrigeration System
The condensation process of non-azeotropic mixed refrigerant is a isobaric process. Meanwhile, the concentrations of vapor and liquid continuously change.
Rui Shengjun, Zhang Hua, He Tao, Luo Hao
doaj +1 more source
Modern aircraft increasingly utilizes highly integrated electronic equipment, driving continuously increasing heat dissipation demands. Vapor compression refrigeration systems demonstrate stronger alignment with future aircraft thermal management trends,
Hainan Zhang +4 more
doaj +2 more sources
In order to study the performance of the new environment-friendly refrigerant mixture, chemical simulation software was used in this study to simulate the compressor exhaust temperature, compression work, evaporator evaporation temperature, system ...
LIU Yang +3 more
doaj +1 more source
Performance of a Small-sized Auto-cascade Refrigerator with a Fractionation Heat Exchanger
A fractionation heat exchanger was employed to improve the separation efficiency of CO2 and propane in the small-sized auto-cascade refrigeration cycle.
Zhang Li +5 more
doaj +1 more source
Molecular dynamics simulation of non-azeotropic refrigerants separation in auto-cascading refrigeration [PDF]
The core problem of auto-cascading refrigeration is the separation of non-azeotropic refrigerants. The separation effect of mixed refrigerant directly determines the refrigeration effect of auto-cascading refrigeration system and the value of COP. The microscopic molecular dynamics simulation method is applied to the refrigeration system, and the ...
Zheng Dayu +3 more
openaire +2 more sources

