Results 241 to 250 of about 4,299,289 (272)
Some of the next articles are maybe not open access.
IEEE Transactions on Industry Applications, 1990
For many years, single-phase static phase converters have been used to supply power to three-phase motors from single-phase distribution systems. However, the main disadvantage on many loads is that while virtually perfect current balance can be obtained at a given load, the balance cannot be maintained over a wide motor-load range.
L.H. Soderholm, C.M. Hertz
openaire +1 more source
For many years, single-phase static phase converters have been used to supply power to three-phase motors from single-phase distribution systems. However, the main disadvantage on many loads is that while virtually perfect current balance can be obtained at a given load, the balance cannot be maintained over a wide motor-load range.
L.H. Soderholm, C.M. Hertz
openaire +1 more source
Digital Signal Processing, 2018
Abstract For antenna array with large number of elements, the multistage Wiener filter (MWF) is an efficient method to perform reduced-rank beamforming. Similar to the generalized sidelobe canceller (GSC), MWF is also sensitive to direction of arrival (DOA) mismatch of the signal of interest (SOI).
Shuang Qiu 0005 +4 more
openaire +2 more sources
Abstract For antenna array with large number of elements, the multistage Wiener filter (MWF) is an efficient method to perform reduced-rank beamforming. Similar to the generalized sidelobe canceller (GSC), MWF is also sensitive to direction of arrival (DOA) mismatch of the signal of interest (SOI).
Shuang Qiu 0005 +4 more
openaire +2 more sources
2005 IEEE International Conference on Industrial Technology, 2006
Most oversized three-phase induction motors operate with low efficiency and power factor, which is by far the most important cause of poor power factor in industrial installations. In the low-load operating periods, motor performance can be improved both in terms of efficiency and power factor through stator-winding connection change from delta to star.
F.J.T.E. Ferreira +4 more
openaire +1 more source
Most oversized three-phase induction motors operate with low efficiency and power factor, which is by far the most important cause of poor power factor in industrial installations. In the low-load operating periods, motor performance can be improved both in terms of efficiency and power factor through stator-winding connection change from delta to star.
F.J.T.E. Ferreira +4 more
openaire +1 more source
IEEE Transactions on Power Electronics, 2013
This paper proposes the dual nondeadtime variable sampling slope technique to carry out precise phase sensing and suppress phase error in interleaving power factor correction (PFC) controller over a whole ac switching cycle for low current mismatch. Furthermore, the proposed automatic loading detection (ALD) technique can keep efficiency higher than 92%
Yi-Ping Su +10 more
openaire +1 more source
This paper proposes the dual nondeadtime variable sampling slope technique to carry out precise phase sensing and suppress phase error in interleaving power factor correction (PFC) controller over a whole ac switching cycle for low current mismatch. Furthermore, the proposed automatic loading detection (ALD) technique can keep efficiency higher than 92%
Yi-Ping Su +10 more
openaire +1 more source
Automatically Determining Lumbar Load During Physically Demanding Work: A Validation Study
Sensors, 2021Charissa Roossien, Bart Verkerke
exaly
Linguistica Antverpiensia, New Series – Themes in Translation Studies, 2020
Jan-Louis Kruger, Stephen Doherty
exaly
Jan-Louis Kruger, Stephen Doherty
exaly
A Method of Automatically Assessing Load Transfer Costs in Substation Optimization Studies
IEEE Transactions on Power Apparatus and Systems / Technical Operations Committee, 1985H Willis, R W Powell
exaly +2 more sources

