Results 21 to 30 of about 501 (138)

First Report on Atrial Leadless Pacing in an Extra-Cardiac Fontan Patient. [PDF]

open access: yesPacing Clin Electrophysiol
ABSTRACT No reports on atrial leadless pacing have been demonstrated in patients with the extra‐cardiac Fontan palliation. We present a case of a patient with an extra‐cardiac Fontan and an alternative to pacing for symptomatic bradycardia in the setting of sinus node dysfunction.
Cortez D.
europepmc   +2 more sources

Dual-chamber leadless pacemaker implant via the RIJ after failed femoral vein implant in a 65-year-old patient with symptomatic bradycardia, with left IJ port and right-sided AV fistula

open access: yesIndian Pacing and Electrophysiology Journal
Introduction: Sinus node dysfunction (SND) is a disorder defined by abnormal initiation and conduction of electrical signals from the sinoatrial node. The preferred first-line treatment for a patient with symptomatic SND is a permanent pacemaker implant.
Shivani Lawa   +3 more
doaj   +1 more source

The Role of Electrophysiologic Study in Device Selection for Leadless Atrial Pacing [PDF]

open access: yesTexas Heart Institute Journal
The AVEIR DR (Abbott Medical) was the first dual-chamber leadless pacing system approved by the US Food and Drug Administration. Many patients with sinus node dysfunction have physiologically normal atrioventricular conduction, so an atrial-only pacing ...
Joshua R. Hirsch, MD   +3 more
doaj   +1 more source

First Report on Atrial Leadless Pacing in a Lateral Tunnel Fontan Patient. [PDF]

open access: yesJ Cardiovasc Electrophysiol
ABSTRACT Introduction No reports on atrial leadless pacing have been demonstrated in patients with the Fontan palliation. We present the case of a patient with a Lateral tunnel Fontan palliation with leadless pacing system for symptomatic bradycardia in the setting of sinus node dysfunction. Methods After internal review board approval, a retrospective
Cortez D, Anza OA, Alnoor M.
europepmc   +2 more sources

Análise da construção e do comportamento duma ponte de pedra [PDF]

open access: yes, 2007
Tese de mestrado. Estruturas de Engenharia Civil. Faculdade de Engenharia. Universidade do Porto, Departamento de Engenharia Civil.
Costa, Pedro Miguel Quintela Marques da
core   +1 more source

Island City [PDF]

open access: yes, 2023
Poster editado num livro sobre o curso Investigação em Design incluído no Programa de Doutoramento em Design da Universidade do Porto e da Universidade de ...
Roberti, Ana Clara   +2 more
core   +1 more source

Leadless Pacemaker Implantation in High‐Risk Patients: Real‐World Outcomes From a Multicenter Israeli Registry

open access: yesPacing and Clinical Electrophysiology, EarlyView.
ABSTRACT Introduction Transvenous pacemakers are effective but carry significant short‐ and long‐term complications. Leadless pacemakers were developed to overcome these limitations, however, data in high‐risk patients ineligible for transvenous systems remain limited.
Moshe Katz   +7 more
wiley   +1 more source

Fabrico rápido de ferramentas por fundição de precisão [PDF]

open access: yes, 2002
Dissertação de doutoramento. Engenharia Mecânica. 2002. Faculdade de Engenharia. Universidade do Porto, Departamento de Engenharia Cerâmica e do Vidro.
Duarte, Teresa Margarida Guerra Pereira
core   +1 more source

Revisão da LIteratura: um trabalho científico

open access: yes, 2022
Seminário no Programa Doutoral em Educação,na Disciplina de Metodologias de Investigação em Educação, da Universidade de ...
Pinho, Isabel
core   +1 more source

Mapping the future: Predictive value of commanded electrogram parameters for the pacing performance in active-fixation leadless pacemakers

open access: yesHeart Rhythm O2
Background: In Aveir VR (Abbott Medical) leadless pacemaker implantation, commanded electrograms (cEGMs) are used before and after fixation to evaluate the suitability of the fixation site.
Takehiro Nomura, MD, PhD   +4 more
doaj   +1 more source

Home - About - Disclaimer - Privacy