Results 31 to 40 of about 501 (138)
ABSTRACT Background Leadless pacemakers traditionally rely on femoral venous access, which may be limited in patients with unfavorable IVC anatomy, prior interventions, or situations where preserving femoral access is preferred. Internal jugular (IJ) access offers an alternative route, but real‐world data on IJ implantation of single‐ and dual‐chamber ...
Maya Asami Takagi +3 more
wiley +1 more source
Late Extraction of Micra AV and Implantation of Right Atrial Leadless Pacemaker
ABSTRACT Background Tine‐based leadless pacemakers have been commercially implanted over the last 10 years. Retrieval of older devices is rarely discussed and based on rare case reports only. Methods A retrospective review of an extraction case of a Micra AV leadless pacemaker was performed. Internal Review Board approval was obtained.
Lydia Fekadu Messele +3 more
wiley +1 more source
ABSTRACT An 88‐year‐old pacemaker‐dependent man with a retained low‐impedance, noise‐producing right ventricular lead underwent implantation of a dual‐chamber leadless pacemaker. On postoperative day 1, he developed recurrent syncope with pauses up to 13 s.
Yuya Nakamura +5 more
wiley +1 more source
A Reassessment of Prophylactic Antibiotics in Low‐Infection‐Risk Electrophysiology Procedures
ABSTRACT Certain electrophysiology (EP) procedures are associated with minimal tissue disruption and do not involve permanent transvenous leads. As a result, these interventions carry a lower risk of device‐ or procedure‐related infection. These procedures include placement of implantable cardiac monitors, leadless pacemakers, and left atrial appendage
Rahel M. Sileshi +14 more
wiley +1 more source
Background The Aveir leadless pacemaker uses an active fixation method, enabling real‐time monitoring of electrical parameters during implantation. However, comprehensive studies on the electrical parameters during this procedure are rare.
Jian‐du Yang +16 more
doaj +1 more source
Although Pulsed field ablation (PFA) has demonstrated efficacy for atrial fibrillation, its safety in patients with leadless pacemaker remains uncertain. This case suggests that extensive PFA involving persistent left superior vena cava, superior vena cava, and left atrial posterior wall can be safely performed without device interference.
Gen Matsuura +4 more
wiley +1 more source
Consortium AVEIR at ImageCLEFphoto 2008: on the fusion of runs
International audienceIn this working note, we present the submission of the AVEIR consortium, composed of 4 French laboratories, to ImageCLEFphoto 2008.
Tollari, Sabrina +9 more
core +1 more source
ABSTRACT Combined use of S‐ICD and LP provides an effective alternative for patients requiring defibrillation and pacing while avoiding transvenous leads. This strategy is particularly valuable for patients with a high risk of infection, though careful consideration must be given to minimizing potential device–device interactions.
ZhaoWei Zhou +3 more
wiley +1 more source
Estudo e análise de uma ponte de arame : um caso de reabilitação [PDF]
Tese de mestrado. Reabilitação do Património Edificado. 2006. Faculdade de Engenharia.
Miranda, Luís Filipe Barbosa
core +1 more source
ABSTRACT Helix‐fixed leadless pacemaker delivery can be challenging after tricuspid annuloplasty with a rigid ring. An 80‐year‐old woman with prior mitral valve repair, tricuspid annuloplasty (26‐mm MC ring), and Maze III surgery presented with syncope due to atrial fibrillation with a slow ventricular response. Standard maneuvers failed to advance the
Yuya Nakamura +5 more
wiley +1 more source