Results 241 to 250 of about 176,371 (293)

Bronchial Compression Following Surgical and Transcatheter Interventions for Coarctation of the Aorta. [PDF]

open access: yesJ Soc Cardiovasc Angiogr Interv
Park J   +7 more
europepmc   +1 more source

Ductility design of RC columns. Part 1: consideration of axial compression ratio

HKIE Transactions, 2016
ABSTRACTTo evaluate and quantify the effect of the axial compression ratio (ACR) on the seismic performance of reinforced concrete (RC) columns, studies of analytical relationships between the axial compression and the mechanical behaviour of RC columns were conducted, followed by a comprehensive statistical analysis with 474 sets of experimental data.
Yuen, Terry Y.P.   +2 more
openaire   +4 more sources

Ductility design of reinforced concrete shear walls with the consideration of axial compression ratio

HKIE Transactions, 2015
To evaluate and quantify the effect of the axial compression ratio on the seismic performance of reinforced concrete walls, a comprehensive statistical analysis with 474 sets of experimental data was conducted. Stipulated limits on the axial compression ratio and their evaluation methods in various design codes were analysed and compared.
Kuang, Jun Shang, Yuen, Y.P.
openaire   +4 more sources

Effects of Axial Compression Ratio in Socketed Precast Pier-Footing Connection

IABSE Congress Reports, 2022
<p>A socket connection is one of the emerging and most recommended joint connections in prefabricated substructures. At present, a large number of researches on socket connections has been carried out and most of them deal with pier-spread footing in the shallow foundation.
Yan Xu, Suresh Shivahari, null ZengZeng
openaire   +1 more source

Axial Compression Ratio Limit of Regional Confined Concrete Columns

Applied Mechanics and Materials, 2013
Through earthquake simulation experiment of nine regional confined concrete columns with different axial compression ratio, the bearing capacity and seismic behavior of regional confined concrete columns were studied in this paper. Considering the ductility, stiffness, energy-dissipation performance and related factors of regional confined concrete ...
Jun Yan Lu, Wei Wang Pang, Shuai Chang
openaire   +1 more source

Experimental Study on Reinforcement Ratio of RCFT Columns under Axial Compression

Advanced Materials Research, 2011
It is clear from the former researches on reinforced concrete filled tubular steel (RCFT) structures that RCFT structures have better performance than concrete filled tubular steel (CFT) structures, in other words, because of the existence of reinforcement, the performance of RCFT differed from that of CFT.
Alifujiang Xiamuxi, Akira Hasegawa
openaire   +1 more source

Effect of Axial Compression Ratio on Seismic Behavior of GFRP Reinforced Concrete Columns

International Journal of Structural Stability and Dynamics, 2020
Traditional reinforced concrete columns have demonstrated poor seismic performance especially in corrosive environment as the reinforcement bars experience severe corrosion under such conditions. To overcome the problem of steel corrosion, glass fiber-reinforced polymer (GFRP) reinforced concrete columns have gained significant attention in recent ...
Li Sun, Zeyu Yang, Qiao Jin, Weidong Yan
openaire   +1 more source

Home - About - Disclaimer - Privacy