Results 131 to 140 of about 48,340 (267)
Receptor‐Free Identification of Toxic Gases Enabled by Hygroscopic Aqueous Salt Films
Water as a gas sensor coating sounds impossible—until it stops evaporating. Here, hygroscopic salt solutions (LiCl, LiBr, H3PO4) form non‐drying aqueous films on CNT chemiresistors under ambient air. Gases partition into these liquid layers, sometimes transforming into water, and generate salt‐specific resistance fingerprints across a four‐channel ...
Seongwoo Lee +5 more
wiley +1 more source
Effect of total ligamentum flavum removal on increased motion and reduced stiffness: an <i>ex vivo</i> biomechanical study in a lamb spine model. [PDF]
Aykaç B +4 more
europepmc +1 more source
Hamaguchi, T., Takada, M., Matsumoto, T.
openaire +1 more source
A swelling‐programmed micropatterned hydrogel guides adherent cells through a controlled transition from cell–matrix anchoring to cadherin‐mediated cell–cell compaction, enabling rapid assembly of high‐viability spheroids with defined size and morphology.
Han Gyeol Nam +8 more
wiley +1 more source
Research on the Axial Compression Performance of Double C-Section Partially Encased Composite Columns. [PDF]
Zhou M, Qin L, Wen X, Wang F, Weng G.
europepmc +1 more source
A three‐dimensional magnetic field sensor is realized in chiral W/CoFeB/MgO multilayers, where spin–orbit torques reversibly reconfigure homochiral stripe domains. The symmetry of the torque enables offset‐free in‐plane sensing, while the reproducible domain reconfiguration extends the linear out‐of‐plane range. An anomalous Hall readout delivers large‐
Sabri Koraltan +16 more
wiley +1 more source
Exploratory Biomechanical Comparison of Three Posterior Pelvic Ring Fixation Strategies in a Standardized Tile C1.2 Synthetic Model. [PDF]
Carp AC +11 more
europepmc +1 more source
Ferroelectric tunnel junction devices based on epitaxial undoped ferroelectric HfO2 films demonstrate stable switching endurance of over 106 switching cycles, low write voltages of ±3 V, 16 measured resistance states, and neuromorphic capability.
Markus Hellenbrand +13 more
wiley +1 more source
Additively manufactured reinforced polymeric stents for peripheral artery disease: design, manufacture and performance evaluation. [PDF]
Bosch A +3 more
europepmc +1 more source
Historical Foundation and Practical Guideline for Ferroelectric Switching Kinetic Studies
The P and U pulses in the conventional PUND measurements are not identical because of the interplay between switching current and the measurement circuit components. This circuit effect can lead to a shift in polarization transients and misinterpreted physics in the switching kinetics.
Yi Liang, Pat Kezer, John T. Heron
wiley +1 more source

