Results 11 to 20 of about 93,869 (311)
Experimental Investigation on Ducted Counter-Rotating Axial Flow Fans [PDF]
An experimental study on counter-rotating axial-flow fans was carried out. The fans of diameter D = 375 mm were designed using an inverse method. The counter-rotating fans operate in a ducted-flow configuration and the overall performances are measured in a normalized test bench. The rotation rate of each fan is independently controlled.
NOURI, Hussain +3 more
openaire +7 more sources
Experimental study of blade thickness effects on the global and local performances of a Controlled Vortex Designed axial-flow fan [PDF]
The purpose of this work is to study the effects of blade thickness on the performances of an axial-flow fan. Two fans that differ only in the thickness of their blades were studied.
BAKIR, Farid +3 more
core +7 more sources
Experimental study of blade rigidity effects on the global and the local performances of a thick blades axial-flow fan [PDF]
An experimental investigation on the aerodynamic performances of thick blades axial-flow fans was carried out in this study. Two fans are considered, the first one is rotomoulded (in plastic) and the second one is milled (in aluminium). Both have exactly
BAKIR, Farid +3 more
core +6 more sources
Nuclear grade axial flow fans are widely used in nuclear power plants for ventilation and heat dissipation and have the advantages of high efficiency and high flow rates.
Weiya Jin +5 more
doaj +1 more source
G100S axial flow fan simulation comparison analysis
Abstract This paper conducts a comparative simulation for different structural layout schemes of the new G100S axial flow fan, with the motor layout position and its supporting guide vane as the main modification direction, while the fan length and guide tongue angle are appropriately adjusted according to the motor position.
Zehao Li +3 more
openaire +1 more source
In this study, some of the optimal parameters for a new-style marine axial flow fan are defined by using numerical simulation and experimental tests with a large marine axial flow fan, based on the analysis of the blade perforation’s influences on its ...
Xinglin Yang +3 more
doaj +1 more source
Investigation of the Unsteady Flow Generated by an Axial Fan: Experimental Testing and Simulations
The unsteady flow measurement of a large axial fan with diameter 1.829m (6 ft) has been carried out. The complex flow field generated by the fan is investigated through experimental testing and CFD/FEA simulation.
R. S. Amano +3 more
doaj +1 more source
The counter-rotating axial flow fan shows that the complex flow characteristics with three-dimensional, viscous, and unsteady flow fields. For the understanding of the entire core flow in counter-rotating axial flow fan, it is necessary to investigate ...
Lee-Sang CHO, Bong-Jun CHA, Jin-Soo CHO
doaj +1 more source
The best efficiency point of an axial fan at low-pressure conditions
In the current work, the objective is to determine the best efficiency point (BEP) of an axial fan using CFD. Analyzing the performance of the fan based upon the parameters chosen can lead to the optimal design of an axial flow fan for aerospace ...
Jose J Corona +4 more
doaj +1 more source
A novel active turbulence grid of the Institute of Fluid Mechanics at FAU Erlangen-Nuremberg is introduced. The focus of this grid is not on basic investigations of fluid mechanics, as is usually the case with active turbulence grids, but the generation ...
Felix Czwielong, Stefan Becker
doaj +1 more source