Results 51 to 60 of about 736 (213)
Cavitation Tests on an Axial Flow Pump
Cavitation tests on an axial flow pump were made over a wide range of operating conditions. Through these tests, the aspects of cavitation in the impeller were observed with a strobolight and variation of the pump characteristics was studied. A parameter σs to represent the suction condition was introduced to give the cavitation limits for any flow ...
HORIE, Chikanobu, KAWAGUCHI, Kyoji
openaire +2 more sources
Miniaturized flow chip platform enabling continuous perfusion and longitudinal multiphoton 3D imaging of vascular smooth muscle cell constructs under physiological flow. Brightfield imaging guides region selection, while CellTracker Green and mRuby‐labeled fetuin‐A visualize cells and mineral deposition, respectively. Magnesium supplementation markedly
Vytautas Kučikas +6 more
wiley +1 more source
Research on bionic pulsation of axial flow blood pump based on LSTM
The micro axial blood pump is one of the most commonly used ventricular assist devices in clinical practice. The axial flow blood pump bionic pulsation device was built to solve the problem that the constant flow assistance does not meet the ...
LUO Yao-Jun, HU Xiao-Bing, WEI Shang-Yun
doaj
Optimizing photoexcitation conditions for time‐resolved X‐ray solution scattering experiments
Time‐resolved X‐ray solution scattering (TR‐XSS) is a powerful technique to visualize how proteins change their structure in real time after light activation. Selecting the right laser photoexcitation conditions—fluence, excitation geometry, and sample refresh rate—is critical to maximize the experimental signal while avoiding unwanted side effects ...
Matteo Levantino
wiley +1 more source
In order to investigate the internal flow characteristics and hydraulic stability of vertical submersible pump station in forward and reverse operation, the steady and unsteady three-dimensional numerical simulation of vertical submersible axial-flow ...
Fan Yang +5 more
doaj +1 more source
We describe detailed protocols for the purification and preparation of Marchantia polymorpha Auxin Response Factor 2 (MpARF2). This protein is fused to an MBP solubility tag and an mNG fluorescent tag and is purified from Escherichia coli. The presented procedures make it possible to study MpARF2 assemblies, which could arise from phase separation ...
Bas Janssen +5 more
wiley +1 more source
A Depolarizing Leak in Sodium Bicarbonate Cotransporter NBCe1 Causes Brain Edema
ABSTRACT Objectives SLC4A4 encodes electrogenic sodium bicarbonate cotransporter NBCe1, prominently expressed in kidney and brain. Recessive loss‐of‐function variants in SLC4A4 cause proximal renal tubular acidosis, no brain edema. In the brain, NBCe1 is expressed by astrocytes, where it regulates pH and mediates astrocyte volume changes.
Quinty Bisseling +16 more
wiley +1 more source
Early Clinical, Imaging, and Pathological Characteristics of SRPK3/TTN‐Digenic Myopathy
ABSTRACT Objective SRPK3/TTN‐digenic myopathy was recently established as a skeletal muscle myopathy caused by digenic inheritance. This study characterizes the early clinical presentation of SRPK3/TTN‐digenic myopathy in one previously reported and seven newly identified pediatric patients.
Rotem Orbach +23 more
wiley +1 more source
White Matter and Perivascular Imaging Changes in Alzheimer's Disease and Cerebral Amyloid Angiopathy
ABSTRACT Objective Peak‐width of skeletonized mean diffusivity (PSMD) and diffusion tensor imaging–analysis along the perivascular space (DTI‐ALPS), reflecting white matter integrity and glymphatic function, are altered in Alzheimer's disease (AD).
Debina Laishram +3 more
wiley +1 more source
INDIRECT METHODS OF MEASURING FLОW RATE AND PRESSURE DROP OF ROTARY BLOOD PUMPS
The article describes complex software to calculate the main parameters of the axial pump (pressure drop and flow rate) on the basis of an analysis of its technical characteristics (current consumption and pump speed).
G. P. Itkin +3 more
doaj +1 more source

