Evaluation of a Macro Lump Plasticity Model for Reinforced Concrete Beam-Column Joint under Cyclic Loading [PDF]
Lateral deformations of reinforced concrete (RC) frames under extreme seismic excitation are highly affected by the stiffness of their beam-column joints.
Joko Purnomo +3 more
doaj +10 more sources
Joint strengthening by external bars on RC beam-column joints [PDF]
The authors wish to thank the financial support provided by the Spanish Ministry of Science and Innovation and the Spanish Ministry of Economy and Competitiveness with Research Projects BIA 2008-06268 and RTI2018-099091-B-C22.
Joaquín G. Ruiz-Pinilla +4 more
core +6 more sources
Seismic damage mechanism of weak beam-column joint frames [PDF]
The use of old building design codes and improper execution of recent seismic design practices resulted in substandard and vulnerable reinforced concrete building stock, the majority of which is built with weak beam-column joint connections (i.e.
Rizwan Muhammad +2 more
doaj +3 more sources
Exterior reinforced concrete beam column joint subjected to monotonic loading [PDF]
The joints between beams and columns are crucial zones in a reinforced concrete moment resisting frame. The behaviour of such joints greatly influences the strength and ductility of the overall frame.
Said M. Allam +2 more
doaj +2 more sources
Numerical Investigation of Textile Reinforced Cement Structural Stay-in-Place Formwork Designed as Beam-Column Joint Shear Reinforcement [PDF]
This study investigates the feasibility and structural performance of textile reinforced cement (TRC) stay-in-place (SiP) formwork designed as shear reinforcement for beam-column joints under monotonic loading through the nonlinear finite element package
Negasa Desta +2 more
doaj +2 more sources
Design of PC beam-column joint applied X-braced bars in the segmented structural system [PDF]
This study suggests a joint design using an X-brace bar to identify the stability and structural performance of a precast concrete (PC) beam-column joint design, which may cause problems when used in a segmented PC beam system for a long-span structure ...
Sijun Kim +3 more
doaj +3 more sources
Finite Element Analysis of Reinforced Concrete Beam-Column Connections with Governing Joint Shear Failure Mode [PDF]
Reinforced concrete (RC) beam-column connections especially those without transverse reinforcement in joint region can exhibit brittle behavior when intensive damage is concentrated in the joint region during an earthquake event.
M.A. Najafgholipour +3 more
doaj +2 more sources
Seismic behavior of non seismically designed eccentric reinforced concrete beam column joints [PDF]
Non seismically designed eccentric reinforced concrete beam column joints were extensively used in existing reinforced concrete frame buildings, which were found to be vulnerable to seismic action in many incidences.
Liu, Ying +5 more
core +1 more source
Effect of Geometric Parameters on the Behavior of Eccentric RC Beam–Column Joints
Over the last century, the seismic behavior of reinforced concrete (RC) beam–column joints has drawn many researchers’ attention due to their complex stress state.
Mostafa A. Abdel-Latif +5 more
doaj +1 more source
Seismic performance of reinforced concrete interior beam-column joints with novel reinforcement detail [PDF]
Horizontal stirrups are normally required in reinforced concrete (RC) beam-column joints (BCJs) for resisting shear forces in seismic design. For RC moment-resisting frames subjected to a high lateral load, a large number of stirrups are needed in joint ...
Li, Bo +3 more
core +2 more sources

