Results 11 to 20 of about 5,923 (162)

Biaxial Cyclic Loading of Woven Fabrics

open access: yesTextile & Leather Review, 2021
For the purpose of this paper, investigations were carried out on specifically designed fabrics with different structural parameters. The biaxial cyclic loading of fabrics and its consequences were investigated. The weave structures with the smallest weave units (plain weave, basket weave 2/2, rib weave 1/1 (2+2) and rib weave 2/2 (1+1) with the same ...
Brnada, Snježana   +3 more
openaire   +3 more sources

Computational simulation of biaxial fatigue behaviour of lotus-type porous material [PDF]

open access: yesFracture and Structural Integrity, 2016
A computational simulation of low-cycle fatigue behaviour of lotus-type porous material, subjected to biaxial in-phase loading cycles is presented in this paper.
J. Kramberger   +3 more
doaj   +3 more sources

Behaviour of composite solid propellant under biaxial tensile loading

open access: yesPolymer Testing, 2023
Biaxial tensile tests were carried out on cruciform specimens of composite solid propellants. Digital Image Correlation (DIC) was used to measure the strain in the gage section. Experiments were conducted at displacement rates of 1, 50 and 1000 mm/min (Y
Rajeev Ranjan   +3 more
doaj   +1 more source

The Effect of Biaxial Loading on the Limit Load of Cracked Plates [PDF]

open access: yesVolume 6A: Materials and Fabrication, 2015
To address the issue of the lack of guidance in fitness-for-service codes [1], [2], for biaxial and triaxial effects on fracture, this paper expands on results presented at PVP 2014 [3] for a centre cracked plate by including the effect of plate length and then presents results for single edge and double edge cracked plates.
Meek, Caroline, Ainsworth, Robert
openaire   +3 more sources

Multiaxial fatigue property of type 316 stainless steel using hollow cylinder specimen under combined pull loading and inner pressure [PDF]

open access: yesFracture and Structural Integrity, 2017
Stress controlled multiaxial fatigue test was carried out using a hollow cylinder specimen of type 316 stainless steel. A newly developed fatigue testing machine which can apply push-pull loading and reversed torsion loading and inner pressure to the ...
Takahiro Morishita   +2 more
doaj   +3 more sources

Biaxial fatigue loading of notched composites [PDF]

open access: yesComposites, 1978
Thin-walled, 2.54-cm diameter tubular specimens of graphite/epoxy (Fiberite T300/1034) were fatigue cycled in combinations of axial, torsion al, and internal pressure loading. Two different four-ply layup configura tions were tested: [0/90] s and [±45] s
Philip H. Francis   +3 more
openaire   +2 more sources

Biaxial Loading of Brazilian Disc Samples

open access: yesIOP Conference Series: Earth and Environmental Science, 2023
Abstract The Brazilian test method has been widely used over the past 50 years to determine the indirect tensile strength of brittle materials, such as rocks and concrete. While the behaviour of Brazilian samples under conventional indirect tensile testing has been the subject of much research, the biaxial loading of a Brazilian sample ...
Serati, M.   +3 more
openaire   +2 more sources

Experimental Analysis and Failure Criterion of Plain Concrete Subjected to Biaxial Loading under Fixed Lateral Loading

open access: yesAdvances in Civil Engineering, 2019
By using a rock true triaxial apparatus hydraulic servo machine, biaxial loading experiments including biaxial compression-compression and biaxial compression-tension with fixed lateral loading on plain concretes were conducted and the stress-strain ...
Zhenpeng Yu, Xue Sun, Furong Li
doaj   +1 more source

Strength of composite laminates under biaxial loads

open access: yesApplied Composite Materials, 1996
Five well known failure criteria and one simple progressive model have been used in conjunction with laminate theory, which allows for nonlinear lamina shear behaviour, to predict the initial and final failure strengths of filament wound composite tubes.
M J. Hinton, P. D. Soden, A. S. Kaddour
openaire   +2 more sources

Biaxial Loading Capacity of H-Type Reinforced Concrete Electric Poles [PDF]

open access: yesJournal of Rehabilitation in Civil Engineering
H-type reinforced concrete poles are nowadays widely used as an economical and cost-effective substitute for wooden poles in power transmission lines.
Abolfazl Eslami   +3 more
doaj   +1 more source