Region- and layer-specific investigations of the human menisci using SHG imaging and biaxial testing [PDF]
In this paper, we examine the region- and layer-specific collagen fiber morphology via second harmonic generation (SHG) in combination with planar biaxial tension testing to suggest a structure-based constitutive model for the human meniscal tissue. Five
Bismi Rasheed +7 more
doaj +2 more sources
Single shot quantitative polarized light imaging system for rapid planar biaxial testing of soft tissues [PDF]
Quantitative Polarized Light Imaging (QPLI) is an established technique used to compute the orientation of collagen fibers based on their birefringence.
Michael J. Blair, Kyle P. Quinn
doaj +2 more sources
Viscoelastic Properties of Porcine Pericardium Under Biaxial Tensile Creep and Stress Relaxation: Application for Novel Aortic Valve Bioprosthesis Design [PDF]
To design novel heart valve bioprostheses, it is extremely important to predict leaflet failure and fatigue for 10–20 years, as the aortic valve opens and closes approximately 40 million times per year.
Edward Matjeka +4 more
doaj +2 more sources
Multi-axial strain mapping to characterise structure and material properties of the human hip capsule. [PDF]
The biological composition and spatial arrangement of the tissue's constituents are directly related to its condition and function. Conventional inspection techniques such as optical microscopy and exogenous staining have limited ability to capture the ...
Kabelan J Karunaseelan +4 more
doaj +2 more sources
Development of a biaxial tensile testing machine for pulsed neutron experiments
A biaxial tensile testing method has been used to get macroscopic information on elastoplastic deformation of a thin steel specimen and improve the accuracy of plastic processing of steel materials.
Koji Kiriyama +4 more
doaj +1 more source
Regional biaxial mechanical data of the mitral and tricuspid valve anterior leaflets
The collective data associated with this article presents the biaxial mechanical behavior for six smaller, delimited regions of the mitral valve and tricuspid valve anterior leaflets.
Devin Laurence +10 more
doaj +1 more source
Experimental analysis and biaxial biomechanical behaviour of ex-vivo sheep trachea
Besides surgery, there are currently no other established methods for routine treatment of tracheal pathologies such a tracheal stenosis or tracheal and airway tumors.
Thanyani Pandelani +3 more
doaj +1 more source
Development of Soft Composite Based Anisotropic Synthetic Skin for Biomechanical Testing
Human skin exhibits highly varying mechanical properties, thickness, hardness, and anisotropy by virtue of changing fiber distributions and orientations, across different body locations.
Vivek Gupta +3 more
doaj +1 more source
Biaxial mechanical data of porcine atrioventricular valve leaflets
This dataset contains the anisotropic tissue responses of porcine atrioventricular valve leaflets to force-controlled biaxial mechanical testing. The set includes the first Piola-Kirchhoff Stress and the specimen stretches (λ) in both circumferential and
Samuel Jett +8 more
doaj +1 more source
Development of biaxial tensile testing for porous polymer membranes
Porous polymer membranes are typically polymeric materials that consist of many pores and complex network structures. As a result of these features, the membranes sometimes undergo anisotropic elastoplastic deformation.
Yasuhisa Kodaira +3 more
doaj +1 more source

