Results 61 to 70 of about 429,345 (244)

Organoid Brain‐Machine‐Interface Devices for Central Nervous System Repair

open access: yesAdvanced Science, EarlyView.
We envision organoid brain‐machine‐interface (Organoid‐BMI) devices as new biohybrid bidirectional communication pathways to connect the human CNS and the external world for personalized CNS repair and regeneration. ABSTRACT Central nervous system (CNS) repair and regeneration suffer from tremendous clinical challenges due to current limitations in ...
Yantao Xing   +10 more
wiley   +1 more source

Comparative analysis of functional condition of masseters with patients having the dysfunction of temporomandibukar joints with sagittal and transversal mandible shifts in the traditional method of treatment and in the application of treatment and in the application of transcranial electrical stimulation

open access: yesКубанский научный медицинский вестник, 2015
The comparative analysis of recording the amplitude of bioelectric potentials of masseters with 41 patients having dysfunction of temporomandibular joints (TMJ) with sagittal and transversal mandible shifts in the traditional method of treatment and in ...
A. N. Sidorenko   +6 more
doaj  

Ultrasound‐Activatable Piezoelectric Hydrogel Reprograms Mitochondrial Epigenetics for Osteoarthritis Therapy via the mTOR/GATD3A Axis

open access: yesAdvanced Science, EarlyView.
An ultrasound‐activatable piezoelectric hydrogel reprograms chondrocyte mitochondrial epigenetics via the mTOR/GATD3A axis, clearing damaged mitochondria and alleviating osteoarthritis progression in both mouse models and human cartilage explants. ABSTRACT The avascular nature of cartilage hinders drug delivery for osteoarthritis (OA) therapy.
Hui Zheng   +9 more
wiley   +1 more source

360° size-adjustable microelectrode array system for electrophysiological monitoring of cerebral organoids

open access: yesFrontiers in Bioengineering and Biotechnology
This paper presents a 360°, size-adjustable microelectrode array (MEA) system for the long-term electrophysiological monitoring of cerebral organoids derived from human pluripotent stem cells.
Takashi Ozaki   +3 more
doaj   +1 more source

A Dual‐Modal Wearable PPG Smartwatch with AI‐Enhanced Correction for High‐Accuracy and Continuous AF Burden Assessment

open access: yesAdvanced Science, EarlyView.
ABSTRACT Atrial fibrillation (AF) increases the risk of stroke and heart failure, yet accurate quantification of AF burden in daily life remains difficult. Although smartwatch photoplethysmography (PPG) supports continuous monitoring, complex rhythms and signal noise can impair burden estimation.
Song Zuo   +27 more
wiley   +1 more source

Ultrasound‐Activated Piezoelectric Neuroimmune Hydrogel Orchestrates Neurogenesis‐Macrophage Crosstalk in Diabetic Wound Healing

open access: yesAdvanced Science, EarlyView.
In this work, we design an ultrasound‐activated piezoelectric hydrogel platform (AOEF@AP5+US) that reprograms neurogenesis‐macrophage crosstalk as an integrated strategy to overcome the intertwined barriers of chronic inflammation, peripheral neuropathy, and impaired regeneration in diabetic wounds.
Kai Wang   +13 more
wiley   +1 more source

YAP1‐Driven Pathogenic Fibro‐Adipogenic Progenitors Secrete IL‐6 and FGF21 to Mediate Muscle‐Bone Crosstalk and Promote Bone Loss

open access: yesAdvanced Science, EarlyView.
Fibro‐adipogenic progenitors (FAPs) in atrophic muscle undergo YAP1‐driven pathogenic activation, secreting IL‐6 and FGF21 as bone‐catabolic myokines that mediate muscle‐bone crosstalk and promote bone loss. Genetic or pharmacological targeting of this YAP1‐FAP‐myokine axis rescues skeletal deterioration, identifying FAP‐derived myokines as therapeutic
Xiaoyu Cai   +16 more
wiley   +1 more source

Examination of the bioelectrical activity of the masticatory muscles during Angle’s Class II division 2 therapy with an activator [PDF]

open access: yesVojnosanitetski Pregled, 2014
Background/Aim. The muscles of the orofacial region have great influence on the development of dentition and occlusion formation. It is known that improper function of these muscles is one of the major etiological factors in malocclusion.
Petrović Đorđe   +4 more
doaj   +1 more source

Magnetoelectric Nanoparticles Enable Modulation of Cortical Networks by Low‐Intensity Static Magnetic Fields In Vitro

open access: yesAdvanced Science, EarlyView.
Neuromodulation strategies are increasingly needed to stimulate, restore, or replace altered neuronal activity in disease. Cobalt ferrite‐barium titanate (CFO–BTO) magnetoelectric nanoparticles convert low‐intensity static magnetic fields into local electrical modulation of cortical networks.
Nathalia Cancino‐Fuentes   +13 more
wiley   +1 more source

Differential Tissue‐Coupled Powering for Battery‐Free Injectable Electroceuticals

open access: yesAdvanced Science, EarlyView.
A thread‐like injectable neural stimulator is powered through differential tissue‐coupled powering (DTCP), which harvests RF‐frequency tissue potentials with an elongated receiver while preserving a injectable cross‐section. The system integrates an ASIC, stimulation electrodes, and a portable transmitter, enabling wireless peripheral nerve stimulation,
Han Wu   +13 more
wiley   +1 more source

Home - About - Disclaimer - Privacy