Results 71 to 80 of about 22,235,517 (201)

The Use of Bioelectrical Impedance Analysis in Newborns. The Need for Standardization

open access: yes, 1993
Rapid growth occurs during fetal and neonatal development. The duration and quality of intrauterine development affect neonate body composition. Weight is routinely used to assess and monitor the nutritional status of newborns. Any weight loss or gain in hospitalized newborn infants may reflect shifts in water balance rather than changes in body mass ...
Gartner, Agnès   +5 more
openaire   +3 more sources

Use of foot-to-foot bioelectrical impedance analysis in children

open access: yes, 2003
The aim of this study was to compare two methods of measuring body composition in children aged 6-10 years: with a traditional bioelectrical impedance analyser and a foot-to-foot impedance device.
Di Giorgio, G   +11 more
core   +1 more source

Copeptin levels remain unchanged during the menstrual cycle [PDF]

open access: yes, 2014
Copeptin, a surrogate marker for arginin vasopressin production, is evaluated as an osmo-dependent stress and inflammatory biomarker in different diseases.
Christian Schindler (71594)   +23 more
core   +1 more source

Confirmation of the reference impedance ratios used for assessment of breast cancer-related lymphedema by bioelectrical impedance spectroscopy

open access: yes, 2011
Background: Breast cancer-related lymphedema in the arm is commonly detected by bioelectrical impedance spectroscopy as an increased inter-arm impedance ratio due to the presence of excess lymph in the at-risk arm relative to that of the unaffected arm ...
S. Czerniec   +14 more
core   +1 more source

Reproducibility of fluid status measured by bioelectrical impedance analysis in healthy volunteers: a key requirement to monitor fluid status in the intensive care unit

open access: yes, 2021
INTRODUCTION: Little is known about the use of bioelectrical impedance analysis (BIA) in critically ill patients. The objective of this study was to evaluate the reproducibility of BIA measurements by comparing non-dominant versus dominant body-side ...
Matthias Gijsen   +12 more
core   +1 more source

Association of bioimpedance‐derived parameters with pulse wave velocity: Phase angle, extracellular to intracellular water ratio, and body cell mass

open access: yesPhysiological Reports
This study investigated the association between parameters derived from bioelectrical impedance spectroscopy (BIS) and arterial stiffness, as measured using carotid–femoral pulse wave velocity (cfPWV) and brachial‐ankle pulse wave velocity (baPWV) pulse ...
Yujiro Asano   +8 more
doaj   +1 more source

Prevalence of child malnutrition at a university hospital using the World Health Organization criteria and bioelectrical impedance data

open access: yesBrazilian Journal of Medical and Biological Research, 2016
Malnutrition constitutes a major public health concern worldwide and serves as an indicator of hospitalized patients’ prognosis. Although various methods with which to conduct nutritional assessments exist, large hospitals seldom employ them to diagnose ...
V.N. Pileggi   +3 more
doaj   +1 more source

Bioelectrical impedance analysis

open access: yes
137 men were evaluated for fertility between April 2024 and April 2025 due to their reproductive needs. Their body composition was analyzed through bioelectrical impedance and related studies were conducted on sperm ...
liu, huang
core   +1 more source

Evaluation of foot-to-foot bioelectrical impedance analysis for the prediction of total body water in oncology outpatients receiving radiotherapy

open access: yes, 2004
Objective: To investigate the accuracy of total body water (TBW) predicted by foot-to-foot bioelectrical impedance compared with a deuterium oxide dilution technique in oncology outpatients receiving ...
Davies, P.S.W.   +7 more
core   +1 more source

Bioelectrical impedance characteristics and screening rate.

open access: yes, 2022
Bioelectrical impedance characteristics and screening rate.
Liang Xu (102656)   +8 more
core   +1 more source

Home - About - Disclaimer - Privacy