Bioelectrical impedance spectroscopy for the assessment of body fluid volumes of term neonates
The assessment of fluid volume in neonates by a noninvasive, inexpensive, and fast method can contribute significantly to increase the quality of neonatal care.
Ferreira D.M., Souza M.N.
doaj +1 more source
Non-destructive characterisation of structural ceramics using impedance spectroscopy [PDF]
This thesis was submitted for the degree of Doctor of Philosophy and awarded by Brunel University.The aim of this project was to explore the potential applications of impedance spectroscopy (IS) in the non-destructive characterisation of structural ...
Wang, Xin
core +7 more sources
Pseudomonas aeruginosa can be detected in a polymicrobial competition model using impedance spectroscopy with a novel biosensor [PDF]
Electrochemical Impedance Spectroscopy (EIS) is a powerful technique that can be used to elicit information about an electrode interface. In this article, we highlight six principal processes by which the presence of microorganisms can affect impedance ...
Tucker, Nicholas P +2 more
core +5 more sources
Evaluation of Bioelectrical Impedance Analysis for Identifying Overweight Individuals at Increased Cardiometabolic Risk:A Cross-Sectional Study [PDF]
OBJECTIVE: To investigate whether bioelectrical impedance analysis could be used to identify overweight individuals at increased cardiometabolic risk, defined as the presence of metabolic syndrome and/or diabetes.DESIGN AND METHODS: Cross-sectional study
Lamb Maxine J. E. +15 more
core +1 more source
Are Ethnic and Gender Specific Equations Needed to Derive Fat Free Mass from Bioelectrical Impedance in Children of South Asian, Black African-Caribbean and White European Origin? Results of the Assessment of Body Composition in Children Study [PDF]
Background Bioelectrical impedance analysis (BIA) is a potentially valuable method for assessing lean mass and body fat levels in children from different ethnic groups.
Cook Derek G. +43 more
core +1 more source
Body composition in Nepalese children using isotope dilution: the production of ethnic-specific calibration equations and an exploration of methodological issues. [PDF]
Background. Body composition is important as a marker of both current and future health. Bioelectrical impedance (BIA) is a simple and accurate method for estimating body composition, but requires population-specific calibration equations. Objectives. (1)
Carlos S. Grijalva-Eternod +17 more
core +2 more sources
Assessment of volume depletion in children with malaria [PDF]
Background The degree of volume depletion in severe malaria is currently unknown, although knowledge of fluid compartment volumes can guide therapy. To assist management of severely ill children, and to test the hypothesis that volume changes in fluid ...
Timothy Planche +47 more
core +2 more sources
Bioelectrical impedance characteristics and screening rate.
Bioelectrical impedance characteristics and screening rate.
Liang Xu (102656) +8 more
core +1 more source
BackgroundBioelectrical impedance analysis (BIA) is widely used to measure body composition but has not been adequately evaluated in infancy. Prior studies have largely been of poor quality, and few included healthy term-born offspring, so it is unclear ...
Jaz Lyons-Reid +18 more
doaj +1 more source
Background Oedema, characterized by accumulation of extracellular water (ECW), is one of the major clinical manifestations in children suffering from nephrotic syndrome (NS).
Steven Brantlov +5 more
doaj +1 more source

